Nissan Sentra B18 (2020-2025) Service Manual: Trunk Opener Request Switch
Component Function Check
Component Function Check
-
CHECK FUNCTION
-
CONSULT-
Select "Request switch BD/TR" in "Data Monitor" mode of "BCM(TRUNK)".
-
Select that the function operates normally according to the following conditions:
Monitor item
Condition
Status
Request switch BD/TR
Trunk lid opener request switch
Pressed
On
Released
Off
-
Is the inspection result normal?
YES >>Trunk lid opener request switch is OK.
NO >>Refer to Diagnosis Procedure.
-
Diagnosis Procedure
Diagnosis Procedure
-
CHECK TRUNK LID OPENER REQUEST SWITCH OUTPUT SIGNAL
-
-
Ignition switch OFF.
-
Check voltage between trunk lid opener request switch harness connector and ground.
(+)
(–)
Voltage
(Approx.)
Trunk lid opener request switch
Connector
Terminal
B14
1
Ground
Battery voltage
-
Is the inspection result normal?
YES >>GO TO 3.
NO >>GO TO 2.
-
-
CHECK TRUNK LID OPENER REQUEST SWITCH CIRCUIT
-
-
Disconnect BCM connector and trunk lid opener request switch connector.
-
Check continuity between BCM harness connector and trunk lid opener request switch harness connector.
BCM
Trunk lid opener request switch
Continuity
Connector
Terminal
Connector
Terminal
M85
98
B14
1
Yes
-
Check continuity between BCM harness connector and ground.
BCM
—
Continuity
Connector
Terminal
M85
98
Ground
No
-
Is the inspection result normal?
YES>>Replace BCM. Refer to Removal and Installation.
NO>>Repair or replace harness.
-
-
CHECK TRUNK LID OPENER REQUEST SWITCH GROUND CIRCUIT
-
-
Disconnect trunk lid opener request switch connector.
-
Check continuity between trunk lid opener request switch harness connector and ground.
Trunk lid opener request switch
—
Continuity
Connector
Terminal
B14
4
Ground
Yes
-
Is the inspection result normal?
YES >>GO TO 4.
NO >>Repair or replace harness.
-
-
CHECK TRUNK LID OPENER REQUEST SWITCH
-
Refer to Component Inspection.
Is the inspection result normal?
YES >>GO TO 5.
NO >>Replace trunk lid opener request switch. Refer to Removal and Installation.
-
-
CHECK INTERMITTENT INCIDENT
-
Refer to Intermittent Incident.
Inspection End.
-
Component Inspection
Component Inspection
-
CHECK TRUNK LID OPENER REQUEST SWITCH
-
-
Ignition switch OFF.
-
Disconnect trunk lid opener request switch connector.
-
Check continuity between trunk lid opener request switch terminals.
Trunk lid opener request switch
Condition
Continuity
Terminals
1
4
Trunk lid opener request switch
Pressed
Yes
Released
No
-
Is the inspection result normal?
YES>>Inspection End.
NO>>Replace trunk lid opener request switch. Refer to Removal and Installation.
-
Other materials:
Before Replacing ECM
SAVE ECM DATA
With CONSULT
Turn ignition switch OFF.
Reconnect all harness connectors
disconnected.
Turn ignition switch ON.
Select “SAVING DATA FOR REPLC
...
License Plate Lamp Circuit
Component Function Check
Component Function
Check
CHECK TAIL LAMP LH OPERATION
Check that tail lamp LH is turned ON when lighting
switch is turned 1ST.
Is the inspection result normal?
YES >>
GO TO 2.
...
P2769-00 Torque Converter Clutch
Dtc Description
DTC Description
DTC DETECTION LOGIC
DTC
CONSULT screen terms
(Trouble diagnosis
content)
DTC detection
conditi ...