Description
Air conditioning system performs self-diagnosis, operation check, function diagnosis, and various settings using diagnosis function of each control unit.
|
ECU |
Diagnostic item (CONSULT) |
|
|---|---|---|
|
A/C auto amp. |
|
Self Diagnostic Result |
|
Data Monitor |
||
|
Active Test |
||
|
Work support |
||
|
BCM |
|
Self Diagnostic Result |
|
Data Monitor |
||
|
ECM |
|
Self Diagnostic Result |
|
Data Monitor |
||
|
IPDM E/R |
|
Self Diagnostic Result |
|
Data Monitor |
||
|
Auto active test |
||
Consult Function (hvac)
CONSULT performs the following functions via CAN communication with A/C auto amp.:
|
Diagnostic mode |
CGW Status |
Description |
||
|---|---|---|---|---|
|
Restricted Mode |
Diag Test Mode |
Open Mode |
||
|
Self Diagnostic Result |
Display |
Display |
Display |
Display non-network DTC which A/C auto amp. memorizes. |
|
CGW Information |
Display |
Display |
Display |
|
|
Data Monitor |
Display |
Display |
Display |
Displays the input/output signal of A/C auto amp. |
|
Active Test |
Non display |
Display |
Display |
The signals used to activate each device are forcibly supplied from A/C auto amp. |
|
Work support |
Non display |
Non display |
Display |
Changes the setting for each setting function. |
|
ECU Identification |
Display |
Display |
Display |
Displays the part number of A/C auto amp. |
|
Network-DTC* |
Display |
Display |
Display |
Display network DTC which A/C auto amp. memorizes when performing “Diagnosis (All System)”. |
*: Displays when performing “Diagnosis (All System)”.
Note:
Diagnosis should be performed with engine running. Door motor operation speeds become slower and NO results may be returned even for normal operation if battery voltage drops below 12 V during self-diagnosis.
SELF DIAGNOSTIC RESULT
Diagnosis result that is judged by A/C auto amp. can be checked. Refer to DTC Index.
CGW INFORMATION
Display the diagnosis mode which a user can perform in Diag Test mode/Open Mode by switching the CGW status from Restricted mode to Diag Test Mode/Open Mode.
DATA MONITOR
Input/output signal of A/C auto amp. can be checked.
Note:
The following table includes information (items) inapplicable to this Nissan Sentra vehicle: For information (items) applicable to this vehicle, refer to CONSULT display items.
|
Monitor item [Unit] |
Description |
|
|---|---|---|
|
AMB TEMP SEN |
[°C] |
Ambient temperature signal value received from combination meter via CAN communication. |
|
IN-VEH TEMP |
[°C] |
In-Nissan Sentra vehicle temperature value converted from in-vehicle sensor signal received from in-vehicle sensor. |
|
INT TEMP SEN |
[°C] |
Evaporator fin temperature value converted from intake sensor signal received from intake sensor. |
|
SUNLOAD SEN |
[W/m^2] |
Sunload value converted from sunload sensor signal received from sunload sensor. |
|
AMB SEN CAL |
[°C] |
Ambient temperature value calculated by A/C auto amp. |
|
IN-VEH CAL |
[°C] |
In-Nissan Sentra vehicle temperature value calculated by A/C auto amp. |
|
INT TEMP CAL |
[°C] |
Evaporator fin temperature value calculated by A/C auto amp. |
|
SUNL SEN CAL |
[W/m^2] |
Sunload value calculated by A/C auto amp. |
|
XM |
Target discharge air temperature (Driver side) judged by A/C auto amp. depending on the temperature setting and the value from each sensor. |
|
|
FAN REQ SIG |
[On/Off] |
Displays blower fan ON signal ON/OFF status transmitted to ECM. |
|
FAN DUTY |
[%] |
Duty ratio of blower motor judged by A/C auto amp. |
|
COMP REQ SIG |
[On/Off] |
Displays A/C ON signal ON/OFF status transmitted to ECM. |
|
A/C comp clutch status |
[On/Off] |
A/C compressor status judged from the A/C compressor feedback signal received from IPDM E/R via CAN communication. |
|
Cooling fan request |
[%] |
Displays cooling fan speed request signal transmitted to ECM via CAN communication. |
|
Rear window defogger request |
[On/Off] |
Display the rear window defogger request signal ON/OFF status transmitted to BCM via CAN communication. |
|
Eco mode request |
[Not REQ/ Request] |
Display the drive mode signal received from BCM via CAN communication. |
|
Illumination control duty |
[%] |
Display the illumination control output duty signal received from combination meter via CAN communication. |
|
Refrigerant PRESS SEN value |
[Bar] |
Display the refrigerant pressure sensor signal received from ECM via CAN communication. |
|
Heated steering wheel request |
Note:
This item displayed, but cannot be monitored. |
|
|
Nissan Sentra Vehicle speed |
[km/h] |
Nissan Sentra Vehicle speed signal value received from ABS actuator and electric unit (control unit) via CAN communication. |
|
ODO/TRIP METER |
[km] |
Odometer signal value received from ABS actuator and electric unit (control unit) via CAN communication. |
|
Engine RPM |
[rpm] |
Engine speed signal value received from ECM via CAN communication. |
|
ENG COOL TEMP |
[°C] |
Engine coolant temperature signal value received from ECM via CAN communication. |
ACTIVE TEST
The signals used to activate each device forcibly supplied from A/C auto amp. operation check of air conditioning system can be performed.
|
Test item |
Description |
|---|---|
|
HVAC TEST |
The operation check of air conditioning system can be performed by selecting the mode. Refer to the following table for the conditions of each mode. |
Check each output device
|
Test item |
|||||||
|---|---|---|---|---|---|---|---|
|
MODE 1 |
MODE 2 |
MODE 3 |
MODE 4 |
MODE 5 |
MODE 6 |
MODE 7 |
|
|
Mode door motor position |
VENT |
VENT |
B/L |
B/L |
FOOT |
D/F |
DEF |
|
Intake door motor position |
REC |
REC |
20% FRE |
20% FRE |
FRE |
FRE |
FRE |
|
Air mix door motor (driver side) position |
FULL COLD |
FULL HOT |
FULL COLD |
FULL HOT |
FULL HOT |
FULL HOT |
FULL HOT |
|
Air mix door motor (passenger side) position |
FULL COLD |
FULL HOT |
FULL COLD |
FULL HOT |
FULL HOT |
FULL HOT |
FULL HOT |
|
Blower motor control signal (duty ratio) |
35% |
35% |
61% |
61% |
89% |
89% |
35% |
|
Magnet clutch (A/C compressor request signal) |
ON |
ON |
ON |
ON |
OFF |
OFF |
ON |
|
ECV duty ratio |
80% |
80% |
40% |
40% |
0% |
0% |
90% |
Perform the inspection of each output device after starting the engine because the A/C compressor is operated.
WORK SUPPORT
Setting change of each setting functions can be performed.
|
Work support items |
Description |
Display |
Setting |
|---|---|---|---|
|
TEMP SET CORRECT |
If the temperature felt by the customer is different from the air flow temperature controlled by the temperature setting, the A/C auto amp. control temperature can be adjusted to compensate for the temperature setting. |
3.0°C |
Note:
When −3.0°C is corrected on the temperature setting set as 25.0°C the temperature controlled by A/C auto amp. is 25.0°C −3.0°C = 22.0°C and the temperature becomes lower than the temperature setting. |
|
2.5°C |
|||
|
2.0°C |
|||
|
1.5°C |
|||
|
1.0°C |
|||
|
0.5°C |
|||
|
0.0°C* |
|||
|
−0.5°C |
|||
|
−1.0°C |
|||
|
−1.5°C |
|||
|
−2.0°C |
|||
|
−2.5°C |
|||
|
−3.0°C |
|||
|
REC MEMORY SET |
If the ignition switch is placed to the OFF position while the intake switch is set to ON (recirculation), “Perform the memory” or “Do not perform the memory” of intake switch ON (recirculation) condition can be selected. |
USE* |
|
|
NOT USE |
|
||
|
FRE MEMORY SET |
If the ignition switch is placed to the OFF position while the intake switch is set to OFF (fresh air intake), “Perform the memory” or “Do not perform the memory” of intake switch OFF (fresh air intake) condition can be selected. |
USE |
|
|
NOT USE* |
|
||
|
BLOW SET |
In FOOT mode, the air blowing to DEF can change ON/OFF. |
O/A C/M* |
|
|
O/A O/M |
|
||
|
C/A O/M |
|
||
|
C/A C/M |
|
||
|
TARGET EVAPORATOR TEMP UPPER LIMIT SETTING |
Setting of upper limit value of target evaporator temperature can be changed. Control characteristic of A/C compressor control (freezing protection control and refrigerant discharge amount control) changes according to change of the setting, and then operation ratio of A/C compressor and refrigerant discharge amount are changed. According to change of the setting, control characteristic focusing on the fuel consumption can be adjusted to control characteristic focusing on the cooling capacity. |
DEFAULT* |
Target evaporator temperature upper limit value: 50°F (10°C) |
|
3°C |
Target evaporator temperature upper limit value: 37°F (3°C) |
||
|
5°C |
Target evaporator temperature upper limit value: 41°F (5°C) |
||
|
7°C |
Target evaporator temperature upper limit value: 45°F (7°C) |
*: Initial status
Note:
When the battery cable is disconnected from the negative terminal or when the battery voltage is 10 V or less, the setting for the work support item is set to the value stored 1 minute after most recent ignition switch OFF status.
ECU IDENTIFICATION
Part number of A/C auto amp. can be checked.
Operation
Diagnosis System (ipdm E/r)Common Item
Consult Function (bcm - Common Item)
CONSULT Function
(BCM - COMMON ITEM)
APPLICATION ITEM
CONSULT performs the following functions via CAN
communication with BCM:
Diagnosis mode
...
Back-Up Lamp Relay Circuit
Component Function Check
Component Function
Check
CHECK BACK-UP LAMP OPERATION
Ignition switch ON.
With operating the shift selector, check that the
back-up lamp is turn ...
Removal and Installation
Removal and Installation
REMOVAL
CAUTION:
Be sure to perform “ADDITIONAL
SERVICE WHEN REPLACING INTELLIGENT KEY UNIT” when replacing
Intelligent Key unit. Refer to Work Procedure.
Remove
instrument panel assembly. Refer to Removal and Installation.
Disconn ...