Component Function Check

Component Function Check

  1. CHECK FUNCTION

    1. CONSULT

      1. Select "Trunk/back door" in "Active Test" mode of "BCM(TRUNK)".

      2. Select “On” to check that it works normally.

    Is the inspection result normal?

    YES>>

    Trunk lid opener actuator is OK.

    NO>>

    Refer to Diagnosis Procedure.

Diagnosis Procedure

Diagnosis Procedure

  1. CHECK TRUNK LID OPENER INPUT SIGNAL

      1. Ignition switch OFF.

      2. Disconnect trunk lid opener assembly (ajar switch) connector.

      3. Check voltage between trunk lid opener assembly (ajar switch) harness connector and ground.

      (+)

      (–)

      Condition

      Voltage

      (Approx.)

      Trunk lid opener assembly (ajar switch)

      Connector

      Terminal

      B59

      3

      Ground

      Trunk lid opener switch is pressed

      Battery voltage

    Is the inspection result normal?

    YES >>

    GO TO 3.

    NO >>

    GO TO 2.

  2. CHECK TRUNK LID OPENER ACTUATOR CIRCUIT

      1. Disconnect BCM connector.

      2. Check continuity between BCM harness connector and trunk lid opener assembly (ajar switch) harness connector.

        BCM

        Trunk lid opener assembly (ajar switch)

        Continuity

        Connector

        Terminal

        Connector

        Terminal

        M21

        145

        B59

        3

        Yes

      3. Check continuity between BCM harness connector and ground.

        BCM

        Continuity

        Connector

        Terminal

        M21

        145

        Ground

        No

    Is the inspection result normal?

    YES>>

    Replace BCM. Refer to Removal and Installation.

    NO>>

    Repair or replace harness.

  3. CHECK TRUNK LID OPENER ACTUATOR GROUND CIRCUIT

    1. Check continuity between trunk lid opener assembly (ajar switch) harness connector and ground.

      Trunk lid opener assembly (ajar switch)

      Continuity

      Connector

      Terminal

      B59

      2

      Ground

      Yes

    Is the inspection normal?

    YES>>

    Replace trunk lid opener assembly (ajar switch). Refer to Removal and Installation.

    NO>>

    Repair or replace harness.

    Trunk Lamp Switch
    Component Function Check Component Function Check CHECK FUNCTION CONSULT Select "Back door/trunk lid switch" in "Data Monitor" mode of "BCM(TRUNK)". Check that the function oper...

    Other materials:

    Difference between predicted and actual distances
    The guidelines shown on the Intelligent Around View Monitor are intended for approximate reference only. Actual object distances may vary, particularly on uphill or downhill surfaces or when objects protrude into the driving path. In such cases, objects may appear closer or farther away on the ...

    P0137 Ho2s2
    Dtc Description DTC Description The heated oxygen sensor 2 has a much longer switching time between rich and lean than the air fuel ratio (A/F) sensor 1. The oxygen storage capacity of the three way catalyst (manifold) causes the longer switching time. ...

    U1040 Eng Comm Circuit
    Dtc Description DTC Description DTC DETECTION LOGIC DTC CONSULT screen terms (Trouble diagnosis content) DTC detection condition ...