Nissan Sentra B18 (2020-2025) Service Manual: Secondary Pressure Solenoid Valve Circuit
Diagnosis Procedure
Diagnosis Procedure
-
CHECK HARNESS CONNECTOR
-
Ignition switch OFF.
-
Check the mating condition of TCM harness connector and CVT unit harness connector.
Is the inspection result normal?
YES >>GO TO 2.
NO >>Repair or replace damaged parts.
-
-
CHECK CONNECTOR TERMINAL
-
Disconnect TCM harness connector and CVT unit harness connector.
-
Check the connectors of TCM and CVT unit for water intrusion, or damage or corrosion of the terminals.
Is the inspection result normal?
YES >>GO TO 3.
NO >>Repair or replace damaged parts.
-
-
CHECK DETECTED DTC
Are other solenoid valve malfunctions detected in addition to secondary pressure solenoid valve?
YES >>GO TO 4.
NO >>GO TO 7.
-
CHECK SOLENOID GROUND CIRCUIT - 1
-
Connect TCM harness connector.
-
Check continuity (resistance) between CVT unit harness connector terminal and ground.
CVT unit
—
Continuity (Resistance)
Connector
Terminal
F46
19
Ground
Existed (1 Ω or less)
Is the inspection result normal?
YES >>GO TO 6.
NO >>GO TO 5.
-
-
CHECK SENSOR GROUND CIRCUIT - 2
-
Disconnect TCM harness connector.
-
Check continuity (resistance) between TCM harness connector terminal and CVT unit harness connector terminal.
TCM
CVT unit
Continuity (Resistance)
Connector
Terminal
Connector
Terminal
F23
43
F46
19
Existed (1 Ω or less)
Is the inspection result normal?
YES >>GO TO 6.
NO >>Repair harness or connector.
-
-
CHECK TCM POWER SUPPLY AND GROUND CIRCUITS
Check TCM power supply and ground circuits. Refer to Diagnosis Procedure.
Is the inspection result normal?
YES >>INSPECTION END
NO >>Repair or replace damaged parts.
-
CHECK SECONDARY PRESSURE SOLENOID VALVE CIRCUIT - 1
Check continuity (resistance) between TCM harness connector terminal and CVT unit harness connector terminal.
TCM
CVT unit
Continuity (Resistance)
Connector
Terminal
Connector
Terminal
F23
39
F46
3
Existed (1 Ω or less)
Is the inspection result normal?
YES >>GO TO 8.
NO >>Repair harness or connector.
-
CHECK SECONDARY PRESSURE SOLENOID VALVE CIRCUIT - 2
Check continuity between TCM harness connector terminal and ground.
TCM
−
Continuity
Connector
Terminal
F23
39
Ground
Not existed
Is the inspection result normal?
YES >>GO TO 9.
NO >>Repair harness.
-
CHECK SECONDARY PRESSURE SOLENOID VALVE
Check resistance between CVT unit connector terminals.
CVT unit
Test condition
Resistance
Terminal
3
19
CVT fluid temperature
20°C (68°F)
5.0 – 5.6 Ω
50°C (122°F)
5.5 – 6.8 Ω
80°C (176°F)
6.0 – 8.0 Ω
Is the inspection result normal?
YES >>INSPECTION END
NO >>Replace control valve due to secondary pressure solenoid valve malfunction. Refer to Removal and Installation.
Other materials:
Squeak and Rattle Trouble Diagnoses
Work Flow
Work Flow
CUSTOMER INTERVIEW
Interview the customer if possible, to determine
the conditions that exist when the noise occurs. Use the Diagnostic
Worksheet during the interview to document the facts and conditions
when the noise occurs and any customer's comments; refer ...
C1601-16 Battery Power Supply
Dtc Description
DTC Description
DTC DETECTION LOGIC
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
...
C106e-54 Steering Angle Sensor
Dtc Description
DTC Description
DTC DETECTION LOGIC
DTC No.
CONSULT screen item
(Trouble diagnosis
content)
DTC detection condition
...