Inspection
COMPONENT PART
Check the mounting conditions (looseness, backlash) of each component. Verify the component conditions (wear, damage) are normal.
SHOCK ABSORBER
Check the shock absorber for oil leaks or damage. Replace the components if necessary.
Wheel alignmentDtc/circuit diagnosis
Malfunction area chart
Main line
Branch line
Short circuit
Main line between ipdm-e and dlc circuit
Diagnosis procedure
1.Check connector
Turn the ignition switch off.
Disconnect the battery cable from the negative terminal.
Check the following terminals and connectors fo ...
Interior room lamp
Removal and installation
Removal
Insert a suitable tool into the gap between the headlining and the
interior room lamp and release the interior
room lamp.
Disconnect the harness connector from the interior room lamp.
Installation
Installation is in the reverse order of removal.
Bul ...
Slip indicator lamp
Component Function Check
1.CHECK SLIP INDICATOR LAMP FUNCTION
Check that slip indicator lamp in combination meter turns ON for
approximately 2 seconds after ignition switch
is turned ON.
Is the inspection result normal?
YES >> Inspection End.