Nissan Sentra B18 (2020-2025) Service Manual: Power Supply and Ground Circuit. Diagnosis Procedure
Diagnosis Procedure
Diagnosis Procedure
-
CHECK FUSE
-
Check that the following fuse is not blown:
Signal name
Fuse No.
Capacity
Ignition power supply
49
10 A
Is the fuse blown?
YES >>Replace the blown fuse after repairing the affected circuit.
NO >>GO TO 2.
-
-
CHECK FUSIBLE LINK
-
Check that the following fusible link is not blown:
Signal name
Fusible link No.
Capacity
Battery
H
80 A
Is the fusible link blown?
YES >>Replace the blown fusible link after repairing the affected circuit.
NO >>GO TO 3.
-
-
POWER SUPPLY CIRCUIT CHECK
-
-
Disconnect EPS control unit connector.
-
Check voltage between EPS control unit harness connector and ground.
(+)
(—)
Ignition switch position
EPS control unit
Connector
Terminal
OFF
ON
START
E74
7
Ground
Battery voltage
Battery voltage
Battery voltage
E73
4
0 V
Battery voltage
Battery voltage
-
Is the inspection result normal?
YES >>GO TO 4.
NO >>Repair or replace harness or connector.
-
-
GROUND CIRCUIT CHECK
-
-
Ignition switch OFF.
-
Check continuity between EPS control unit harness connector and ground.
EPS control unit
—
Continuity
Connector
Terminal
E74
8
Ground
Yes
-
Is the inspection result normal?
YES >>Inspection End.
NO >>Repair or replace harness or connectors.
-
Other materials:
U215b-87 Can Comm Err (ipdm E/r)
Dtc Description
DTC Description
DTC DETECTION LOGIC
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
...
Basic Inspection
Diagnosis and Repair Work Flow
Diagnostic Work Sheet
Diagnostic Work Sheet
DESCRIPTION
There are many operating conditions that lead to the malfunction
of engine components. A good grasp of such conditions can make troubleshooting
faster and more accurate.
In general, each custo ...
Vacuum Pump
Exploded View
Exploded View
1.
Vacuum tube
2.
Clamp
3.
Vacuum hose A ...