Description
When the battery negative terminal is disconnected, the initialization is necessary for normal operation of power window system.
CAUTION:
The following specified operations can not be performed under the non-initialized condition.
Work Procedure
1.SYSTEM INITIALIZATION
Perform system initialization. Refer to PWC-29, "Work Procedure".
>> GO TO 2.
2.CHECK ANTI-PINCH FUNCTION
Check anti-pinch function. Refer to PWC-30, "Work Procedure".
>> END
Vanity mirror lamp
Removal and installation
Caution:
Do not attempt to separate the vanity mirror lamp from the sun visor or
damage to the components
may occur.
Note:
The vanity mirror lamp is replaced as part of the sun visor. Refer to
int-40, "removal and installation".
Bulb or lens replacement
...
P0182, P0183 FTT Sensor
DTC Logic
DTC DETECTION LOGIC
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detecting condition
Possible cause
P0182
FTT SEN/CIRCUIT
(Fuel temperature sensor
″A″ circuit low)
An excessively low voltage from the sensor is
sent to ...
SRS Air bag warning lamp does not turn ON
Diagnosis Procedure
1.CHECK COMBINATION METER POWER SUPPLY AND GROUND CIRCUIT
Check combination meter unit power supply and ground circuit. Refer to
MWI-52, "COMBINATION METER :
Diagnosis Procedure".
Is the inspection result normal?
YES >> GO TO 2.