Description
When the battery negative terminal is disconnected, the initialization is necessary for normal operation of power window system.
CAUTION:
The following specified operations can not be performed under the non-initialized condition.
Work Procedure
1.SYSTEM INITIALIZATION
Perform system initialization. Refer to PWC-29, "Work Procedure".
>> GO TO 2.
2.CHECK ANTI-PINCH FUNCTION
Check anti-pinch function. Refer to PWC-30, "Work Procedure".
>> END
Vehicle jerks during vdc/tcs/abs
control
Diagnosis Procedure
1.SYMPTOM CHECK
Check if the vehicle jerks during VDC/TCS/ABS control.
Is the inspection result normal?
YES >> Inspection End.
NO >> GO TO 2
2.CHECK SELF DIAGNOSTIC RESULT
Perform self diagnostic result of ABS actuator and electric unit
(control unit). Re ...
Precaution for Liquid Gasket
Removal of liquid gasket
After removing the bolts and nuts, separate the mating surface and
remove the old liquid gasket using tool.
Tool number : kv10111100 (j-37228)
Caution:
Do not damage the mating surfaces.
Tap the seal cutter to insert it (1).
In areas where the tool is diffic ...
Abs actuator and electric unit (control unit)
Exploded View
ABS actuator and electric unit (control
unit)
ABS actuator and electric unit (control
unit) harness connector
Bushing
Bracket
To master cylinder secondary side
To master cylinder primary side
To rear LH caliper
To front RH caliper
...