Nissan Sentra manuals

Nissan Sentra Service Manual: A-bag branch line circuit

Diagnosis procedure

Warning:

Always observe the following items for preventing accidental activation.

1.Check connector

  1. Turn the ignition switch off.
  2. Disconnect the battery cable from the negative terminal.
  3. Check the terminals and connectors of the air bag diagnosis sensor unit for damage, bend and loose connection (unit side and connector side).

Is the inspection result normal? Yes >> go to 2.

No >> replace the main harness.

2.Check air bag diagnosis sensor unit

Check the air bag diagnosis sensor unit. Refer to src-38, "work flow".

Is the inspection result normal? Yes >> replace the main harness.

No >> replace parts whose air bag system has a malfunction.

Tcm branch line circuit
Diagnosis procedure 1.Check connector Turn the ignition switch off. Disconnect the battery cable from the negative terminal. Check the following terminals and connectors for damage, bend and ...

Dlc branch line circuit
Diagnosis procedure 1.Check connector Turn the ignition switch OFF. Disconnect the battery cable from the negative terminal. Check the terminals and connectors of the data link connector for ...

Other materials:

Unit disassembly and assembly
TRANSAXLE ASSEMBLY Exploded View CASE AND HOUSING Filler plug Gasket Transaxle case Bushing Snap ring Oil channel Oil gutter Position switch Bracket Differential side oil seal Magnet Drain plug Input shaft oil seal Clutch housing 2 way connector Plug Pinion ...

Removal and installation
Nats antenna amp Removal and installation Removal Remove instrument finisher b. Refer to ip-14, "exploded view". Using a suitable tool release the pawls on either side and remove the NATS antenna amp. from the pushbutton ignition switch. Installation Installation is in the ...

P1572 ASCD Brake switch
DTC Logic DTC DETECTION LOGIC NOTE: If DTC P1572 is displayed with DTC P0605, first perform the trouble diagnosis for DTC P0605. Refer to EC-348, "DTC Logic". This self-diagnosis has the one trip detection logic. When malfunction A is detected, DTC is not stored in ECM me ...