Diagnosis Procedure
CHECK TRIP RESET SWITCH SIGNAL
Ignition switch ON.
Check voltage between the following terminals of the trip reset switch harness connector.
|
Trip reset switch |
Condition |
Voltage (Approx.) |
||
|---|---|---|---|---|
|
Connector |
Terminals |
|||
|
(+) |
(−) |
|||
|
M138 |
1 |
2 |
When trip reset switch is pressed |
0 V |
|
Other than the above |
5 V |
|||
Is the inspection result normal?
YES >>Inspection End.
NO >>GO TO 2.
CHECK TRIP RESET SWITCH HARNESS
Ignition switch OFF.
Disconnect combination meter harness connector and trip reset switch harness connector.
Check continuity between combination meter harness connector and trip reset switch harness connector.
|
Combination meter |
Trip reset switch |
Continuity |
||
|---|---|---|---|---|
|
Connector |
Terminal |
Connector |
Terminal |
|
|
M24 |
10 |
M138 |
1 |
Yes |
|
32 |
2 |
|||
Check continuity between combination meter harness connector and ground.
|
Combination meter |
— |
Continuity |
|
|---|---|---|---|
|
Connector |
Terminal |
||
|
M24 |
10 |
Ground |
No |
|
32 |
|||
Is the inspection result normal?
YES >>Inspection End.
NO >>Repair or replace harness or connector.
Component Inspection
CHECK TRIP RESET SWITCH
Ignition switch OFF.
Disconnect trip reset switch harness connector.
Check continuity between the following terminals of the trip reset switch:
|
Trip reset switch |
Condition |
Continuity |
|
|---|---|---|---|
|
Terminals |
|||
|
1 |
2 |
When trip reset switch is pressed |
Yes |
|
Other than the above |
No |
||
Is the inspection result normal?
YES >>Inspection End.
NO >>Replace trip reset switch. Refer to Removal and Installation.
Removal and Installation
Removal and Installation
CAUTION:
All hoses and piping (tubes) must be free from
excessive bending, twisting, and pulling.
Make sure there is no interference with other
parts when turning steering both clockwise and
counter ...
Component Function Check
Component Function
Check
CAUTION:
Before performing the diagnosis, check that the
following are normal:
Interior room lamp power supply circuit
Trunk room lamp bulb
CHECK TRUNK ROOM LAMP OPERATION
...
Dlc branch line circuit
Diagnosis procedure
1.Check connector
Turn the ignition switch off.
Disconnect the battery cable from the negative terminal.
Check the terminals and connectors of the data link connector for
damage, bend and loose connection
(connector side and harness side).
Is the inspection resul ...