Component Parts Function Inspection
1.CHECK SHIFT POSITION INDICATOR
Is the inspection result normal? YES >> INSPECTION END
NO >> Go to TM-240, "Diagnosis Procedure".
Diagnosis Procedure\
1.CHECK TCM INPUT/OUTPUT SIGNAL
With CONSULT
Is the check result normal? YES >> INSPECTION END
NO-1 (“RANGE” is changed but is not displayed on the shift position indicator.>>Check “Self Diagnostic Result” in “TRANSMISSION”.
NO-2 (“RANGE” and shift position indicator are different.)>>Check “Self Diagnostic Result” in “TRANSMISSION”.
NO-3 (Specific“RANGE” is not displayed on the shift position indicator.)>>Check “Self Diagnostic Result” in “METER/M&A”.
P0605 ECM
DTC Logic
DTC DETECTION LOGIC
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detecting condition
Possible cause
P0605
ECM
[Internal control module
read only memory (ROM)
error]
Malfunction in the internal ROM of ECM.
ECM
DTC CONFIRM ...
Seats
WARNING
Do not ride in a moving vehicle when
the seatback is reclined. This can be
dangerous. The shoulder belt will not
be against your body. In an accident,
you could be thrown into it and receive
neck or other serious injuries. You
could also slide under the ...
P1554 Battery current sensor
DTC Logic
DTC DETECTION LOGIC
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detecting condition
Possible cause
P1554
BAT CURRENT SENSOR
(Battery current sensor)
The output voltage of the battery current
sensor is lower than the specified value ...