Nissan Sentra B18 (2020-2025) Service Manual: Service Data and Specifications (sds). Service Data and Specifications (sds)
Service Data and Specifications (sds)
Idle Speed : Service Data
IDLE SPEED : Service Data
|
Transmission |
Condition |
Specification (Approx.) |
|---|---|---|
|
CVT |
No load* (in P or N position) |
650±50 rpm |
|
M/T |
No load* (in Neutral position) |
650±50 rpm |
*: Under the following conditions
-
A/C switch: OFF
-
Electric load: OFF (Lights, heater fan & rear window defogger)
-
Steering wheel: Kept in straight-ahead position
Ignition Timing : Service Data
IGNITION TIMING : Service Data
|
Transmission |
Condition |
Specification (Approx.) |
|---|---|---|
|
CVT |
No load* (in P or N position) |
3±2° BTDC |
|
M/T |
No load* (in Neutral position) |
3±2° BTDC |
*: Under the following conditions
-
A/C switch: OFF
-
Electric load: OFF (Lights, heater fan & rear window defogger)
-
Steering wheel: Kept in straight-ahead position
Calculated Load Value : Service Data
CALCULATED LOAD VALUE : Service Data
|
Condition |
Specification |
|---|---|
|
At idle |
20 – 25 % |
|
At 2,500 rpm |
10 – 15 % |
Mass Air Flow Sensor : Service Data
MASS AIR FLOW SENSOR : Service Data
|
Supply voltage |
5 ± 0.25 V |
|
Output frequency at 1.500 rpm |
5,400 - 5,900 Hz* |
|
Mass air flow (Using CONSULT or GST) |
1.5 – 2.6 g/s at idle* 4.3 – 8.2 g/s at 2,500 rpm* |
*: Engine is warmed up to normal operating temperature and running under no load.
Other materials:
Basic Inspection
Diagnosis and Repair Work Flow
Work Flow
Work Flow
OVERALL SEQUENCE
DETAILED FLOW
GET INFORMATION FOR SYMPTOM
Get detailed information from the customer about
the symptom (the condition and the environment ...
Power Supply and Ground Circuit
A/c Amp.
Diagnosis Procedure
Diagnosis Procedure
CHECK A/C AMP. GROUND CIRCUIT FOR
OPEN
Ignition switch OFF.
Disconnect A/C amp. connector.
...
Manifold Absolute Pressure Sensor
Component Inspection
Component Inspection
CHECK MANIFOLD ABSOLUTE PRESSURE
(MAP) SENSOR-1
Turn ignition switch OFF.
Start engine and warm it up to normal
operating temperature.