Dtc Description
DTC DETECTION LOGIC
|
DTC |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition |
||
|
P28EE |
00 |
EL/AUX T/M FLUID PUMP B (Electric/Auxiliary Transmission Fluid Pump "B" Overspeed) |
Diagnosis condition |
Diagnosis is permitted when all of the following conditions are satisfied: a) Ignition voltage ≥ 9.01 V b) Battery voltage ≥ 9.01 V c) After ignition on, 1 sec has elapsed. d) Target electric oil pump speed ≥ 500 rpm e) Electric oil pump motor temperature ≤ 179 °C (354 °F) |
|
Signal |
— |
|||
|
Threshold |
When the actual electric oil pump speed is lower than the target electric oil pump speed |
|||
|
Diagnosis delay time |
2 seconds |
|||
POSSIBLE CAUSE
Electric oil pump
Control valve
Input voltage
FAIL-SAFE
Stop/start system prohibited
DTC CONFIRMATION PROCEDURE
PREPARATION BEFORE WORK
If another "DTC CONFIRMATION PROCEDURE" occurs just before, ignition switch OFF and wait for at least 10 seconds, then perform the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 10 V.
>>GO TO 2.
CHECK DTC DETECTION
Ignition switch ON and wait for at 20 seconds.
Check the DTC.
Is "P28EE-00" detected?
YES >>Proceed to DTC Diagnosis Procedure.
NO-1>>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2>>Confirmation after repair: INSPECTION END
Dtc Diagnosis Procedure
CHECK ELECTRIC OIL PUMP POWER SUPPLY
Ignition switch OFF.
Disconnect CVT unit harness connector.
Ignition switch ON.
Check voltage between CVT unit harness connector terminal and ground.
|
+ |
- |
Voltage |
|
|---|---|---|---|
|
CVT unit |
|||
|
Connector |
Terminal |
||
|
F56 |
24 |
Ground |
10 - 16 V |
Is the inspection result normal?
YES >>GO TO 3.
NO >>GO TO 2.
CHECK ELECTRIC OIL PUMP POWER SUPPLY CIRCUIT - 1
Check the following items:
Open or short circuit of harness between battery positive terminal and CVT unit harness connector terminal 24.
60A fusible link (No. L)
Is the inspection result normal?
YES >>INSPECTION END
NO >>Repair harness, connector, or fusible link
CHECK ELECTRIC OIL PUMP GROUND CIRCUIT - 1
Ignition switch OFF.
Check continuity between CVT unit harness connector terminal and ground.
|
CVT unit |
- |
Continuity |
|
|---|---|---|---|
|
Connector |
Terminal |
||
|
F56 |
23 |
Ground |
Existed |
Is the inspection result normal?
YES >>GO TO 4.
NO >>Repair or replace damaged parts.
CHECK ELECTRIC OIL PUMP CAN CIRCUIT - 1
Disconnect TCM harness connector.
Check resistance between TCM harness connector terminals and CVT unit harness connector terminals.
|
TCM |
CVT unit |
Resistance |
||
|---|---|---|---|---|
|
Connector |
Terminal |
Connector |
Terminal |
|
|
F23 |
31 |
F46 |
11 |
1 Ω or less |
|
32 |
10 |
|||
Is the inspection result normal?
YES >>GO TO 5.
NO >>Repair harness or connector.
CHECK PRIMARY SPEED SENSOR GROUND CIRCUIT - 2
Remove control valve cover. Refer to Removal and Installation.
CAUTION:
Never disconnect harness connector F102 inside the CVT unit. Refer to Wiring Diagram.
Check continuity between CVT unit connector terminal and electric oil pump harness terminal.
|
CVT unit |
Electric oil pump |
Continuity |
|
|---|---|---|---|
|
Terminal |
Connector |
Terminal |
|
|
23 |
F108 |
5 |
Existed |
Is the inspection result normal?
YES >>GO TO 6.
NO >>Repair harness or connector.
CHECK ELECTRIC OIL PUMP POWER SUPPLY CIRCUIT - 2
Check continuity between CVT unit connector terminal and electric oil pump harness terminal.
|
CVT unit |
Electric oil pump |
Continuity |
|
|---|---|---|---|
|
Terminal |
Connector |
Terminal |
|
|
24 |
F107 |
4 |
Existed |
Is the check result normal?
YES >>GO TO 7.
NO >>Repair harness or connector.
CHECK ELECTRIC OIL PUMP CAN CIRCUIT - 2
Disconnect electric oil pump harness connector.
Check resistance between CVT unit connector terminals and electric oil pump harness connector terminals.
|
CVT unit |
Electric oil pump |
Resistance |
|
|---|---|---|---|
|
Terminal |
Connector |
Terminal |
|
|
10 |
F106 |
2 |
1 Ω or less |
|
11 |
3 |
||
Is the inspection result normal?
YES >>GO TO 8.
NO >>Replace control valve due to harness connector malfunction. Refer to Removal and Installation.
REPLACE ELECTRIC OIL PUMP
Replace electric oil pump. Refer to Removal and Installation.
>>GO TO 9.
CHECK DTC DETECTION
Perform DTC confirmation procedure. Refer to DTC Description.
Is "P28EE-00" detected again?
YES >>Replace control valve. Refer to Removal and Installation.
NO >>INSPECTION END
P28ed-00 Electric Oil Pump
Cvt Belt InspectionRemoval and installation
Generator
Exploded view
Thermostat housing
Generator bolt (upper)
Generator bolt (lower)
Generator
B” terminal harness
“B” terminal nut
Generator harness connector
Front
Removal and installation
Note:
When removing components such as hoses,tubes\lines,etc,ca ...
P10cb Internal Control Module Fuel Injector
Dtc Description
DTC Description
DTC DETECTION LOGIC
DTC
CONSULT screen terms
(Trouble diagnosis
content)
DTC detection
condition
...
Dtc Diagnosis Procedure
DTC Diagnosis
Procedure
CHECK FUSE
Ignition switch OFF.
Check that the following fuse is not blown (open):
...