Nissan Sentra B18 (2020-2025) Service Manual: P119a Fuel Rail Pressure Sensor
Dtc Description
DTC Description
DTC DETECTION LOGIC
|
DTC |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition |
|
|
P119A |
FUEL PRESSURE SENSOR (Fuel pressure sensor) |
Diagnosis condition |
|
|
Signal (terminal) |
Fuel rail pressure sensor signal |
||
|
Threshold |
Fuel rail pressure is less than 1.0 MPa (10.2 kg/cm2, 145 psi) (calculated by ECM) |
||
|
Diagnosis delay time |
— |
||
POSSIBLE CAUSE
-
Harness or connectors
-
The fuel rail pressure sensor circuit is open or shorted.
-
Sensor power supply 2 is shorted.
-
-
Fuel rail pressure sensor
-
Each sensor, connected with sensor power supply 2 circuit
FAIL-SAFE
Not applicable
Confirmation Procedure
Confirmation Procedure
-
PRECONDITIONING-1
If DTC Confirmation Procedure is previously conducted, always perform the following procedure before conducting the next test.
-
Turn ignition switch OFF and wait at least 10 seconds.
-
Turn ignition switch ON.
-
Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, check that battery voltage is 9 V or more with ignition switch ON.
>>GO TO 2.
-
-
PRECONDITIONING-2
Note:
-
When it is certain that the previous driving is performed with the engine warmed up, the next steps can be performed.
-
When it is difficult to satisfy the conditions, performing Component Function Check can identify the presence or absence of malfunction in the part/system that may result in a possible cause of this DTC. (Perform DTC Confirmation Procedure as much as possible.)
-
Start the engine and warm it up until engine coolant temperature reaches 70°C (158°F) or more.
-
Stop the engine and leave the Nissan Sentra vehicle in a cool place (soak the engine) until the engine coolant temperature reaches 35°C (95°F) or less.
CAUTION:
-
The difference between air temperature and engine coolant temperature must be 5°C (9°F) or less.
-
Never turn ignition switch ON during soak the engine.
Are the conditions satisfied?
YES >>GO TO 4.
NO >>GO TO 3.
-
-
COMPONENT FUNCTION CHECK
With CONSULT-
Turn ignition switch OFF.
-
Start the engine and warm it up to normal operating temperature.
-
Select “FUEL PRES SEN V” in “DATA MONITOR” mode of “ENGINE” using CONSULT and check the indication under the following condition.
Monitor item
Condition
Indication
FUEL PRES SEN V
-
Engine: After warming up
-
Selector lever: P or N position (CVT models), Neutral position (M/T models)
-
A/C switch: OFF
-
No load
Engine speed: Idle
0.85 V
Revving engine from idle to 4,000 rpm quickly
0.97 V
-
Without CONSULT-
Turn ignition switch OFF.
-
Start the engine and warm it up to normal operating temperature.
-
Check FRP sensor signal voltage.
ECM
Condition
Voltage
Connector
+
−
Terminal
F24
44
45
[Engine is running]
-
Engine warm-up condition
-
Engine speed: Idle
0.85 V
[Engine is running]
-
Engine warm-up condition
-
Revving engine from idle to 4,000 rpm quickly
0.97 V
-
Is the inspection result normal?
YES >>INSPECTION END.
NO >>Proceed to DTC Diagnosis Procedure.
-
-
PERFORM DTC CONFIRMATION PROCEDURE-1
With CONSULT-
Turn ignition switch ON (engine stopped).
-
Select “COOLANT TEMP/S” and “INT/A TEMP SE” in “DATA MONITOR” mode of “ENGINE” using CONSULT.
-
Check that the indicated value of “COOLANT TEMP/S” is less than 35°C (95°F).
-
Check that the difference between “INT/A TEMP SE” and “COOLANT TEMP/S” is 5°C (41°F) or less.
-
Check “Self-diagnostic result” of “ENGINE”.
Is the DTC detected?
YES >>Refer to DTC Diagnosis Procedure.
NO-1 (Conditions satisfied) >>GO TO 5.
NO-2 (Conditions not satisfied) >>GO TO 2.
-
-
PERFORM DTC CONFIRMATION PROCEDURE-2
-
Start the engine (or cranking) at least 1 second.
-
Check “Self-diagnostic result” of “ENGINE”.
Is the DTC detected?
YES >>Refer to DTC Diagnosis Procedure.
NO-1 >>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2 >>Confirmation after repair: INSPECTION END
-
Dtc Diagnosis Procedure
DTC Diagnosis Procedure
Note:
Turning the ignition switch ON with FRP sensor harness connector disconnected causes ECM to detect DTC P0190. Be sure to erase the DTC when the diagnosis procedure.
-
CHECK FUEL RAIL PRESSURE (FRP) SENSOR POWER SUPPLY-1
-
Turn ignition switch OFF.
-
Disconnect FRP sensor connector.
-
Turn ignition switch ON.
-
Check the voltage between FRP sensor harness connector terminals.
FRP sensor
Voltage
(Approx.)
Connector
+
−
terminal
F101
1
3
5 V
Inspection result normal?
YES >>GO TO 7.
NO >>GO TO 2.
-
-
CHECK FRP SENSOR POWER SUPPLY-2
Check the voltage between FRP sensor harness connector and the ground.
+
−
Voltage
(Approx.)
FRP sensor
Connector
Terminal
F101
1
Ground
5 V
Is inspection result normal?
YES >>GO TO 5.
NO >>GO TO 3.
-
CHECK FRP SENSOR POWER SUPPLY CIRCUIT FOR OPEN AND SHORT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F101
1
F24
43
Existed
-
Also check harness for short to power.
Is inspection result normal?
YES >>GO TO 4.
NO >>Repair or replace error-detected parts.
-
-
CHECK SENSOR POWER SUPPLY 2 CIRCUIT
Refer to Diagnosis Procedure.
Is inspection result normal?
YES >>Perform the trouble diagnosis for ECM power supply circuit. Refer to Diagnosis Procedure.
NO >>Repair or replace error-detected parts.
-
CHECK FRP SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F101
3
F24
45
Existed
-
Also check harness for short to power.
Is inspection result normal?
YES >>GO TO 6.
NO >>Repair or replace error-detected parts.
-
-
CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT
-
Check the continuity between ECM harness connector and ground.
ECM
—
Continuity
Connector
Terminal
F24
5
Ground
Existed
65
F25
69
E16
157
159
162
-
Also check harness for short to power.
Is the inspection result normal?
YES >>INSPECTION END
NO >>Repair or replace error-detected parts.
-
-
CHECK FRP SENSOR SIGNAL CIRCUIT FOR OPEN AND SHORT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F101
2
F24
44
Existed
-
Also check harness for short to ground and to power.
Is inspection result normal?
YES >>GO TO 8.
NO >>Repair or replace error-detected parts.
-
-
CHECK FRP SENSOR
Check the FRP sensor. Refer to Component Inspection.
Is inspection result normal?
YES >>INSPECTION END
NO >>Repair or replace error-detected parts.
Other materials:
Egr Cooler
Exploded View
Exploded View
1.
Vacuum delay valve
bracket
2.
EGR cooler
bracket
...
P0300 Misfire
Dtc Description
DTC Description
When a misfire occurs, engine speed will fluctuate. If the engine
speed fluctuates enough to cause the crankshaft position (CKP) sensor signal to
vary, ECM can determine that a misfire is occurring.
...
Diagnosis System (distance Sensor)
Consult Function (laser/radar)
CONSULT Function (LASER/RADAR)
APPLICATION ITEMS
CONSULT performs the following functions via CAN communication
with ADAS control unit 2 and the communication with distance sensor.
...