DTC DETECTION LOGIC
NOTE:
This diagnosis indicates the former, to detect open or short circuit malfunction.
DTC No. | CONSULT screen terms (Trouble diagnosis content) | DTC detecting condition | Possible cause |
P0462 | FUEL LEVL SEN/CIRC (Fuel level sensor ″A″ circuit low) | An excessively low voltage from the sensor is sent to ECM. |
|
P0463 | FUEL LEVL SEN/CIRC (Fuel level sensor ″A″ circuit high) | An excessively high voltage from the sensor is sent to ECM. |
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is between 11 V and 16 V at ignition switch ON.
>> GO TO 2.
2.PERFORM DTC CONFIRMATION PROCEDURE
Is 1st trip DTC detected? YES >> Proceed to EC-329, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis Procedure
1.CHECK COMBINATION METER FUNCTION
Refer to MWI-17, "CONSULT Function (METER/M&A)".
Is the inspection result normal? YES >> Check intermittent incident. Refer to GI-39, "Intermittent Incident".
NO >> Proceed to MWI-58, "Component Function Check".
The door open warning continues displaying, or does not display
Description
The door ajar warning is displayed even though all of the doors are
closed.
The door ajar warning is not displayed even though a door is ajar.
Diagnosis procedure
1.Check bcm input signal
Check the bcm input signal. Refer to dlk-102, "component function check"
( ...
Cluster lid C
Removal and Installation - Cluster Lid C
REMOVAL
Remove cluster lid C lower. Refer to IP-20, "Removal and Installation -
Cluster Lid C Lower".
Remove the cluster lid C screws (A).
Disconnect the harness connector from cluster lid C.
Remove the center ventilator grill ...
Ecm branch line circuit
Diagnosis Procedure
1.CHECK CONNECTOR
Turn the ignition switch OFF.
Disconnect the battery cable from the negative terminal.
Check the terminals and connectors of the ECM for damage, bend and loose
connection (unit side and
connector side).
Is the inspection result normal?
YES > ...