Nissan Sentra B18 (2020-2025) Service Manual: P0454 Evap System Pressure Sensor
Dtc Description
DTC Description
DTC DETECTION LOGIC
|
DTC |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition |
||
|
P0454 |
00 |
EVAP SYS PRES SEN (EVAP system pressure sensor/switch "A" circuit intermittent) |
Diagnosis condition |
— |
|
Signal (terminal) |
EVAP control system pressure sensor signal |
|||
|
Threshold |
ECM detects a sloshing signal from the EVAP control system pressure sensor |
|||
|
Diagnosis delay time |
— |
|||
POSSIBLE CAUSE
-
Harness or connectors (EVAP control system pressure sensor circuit is shorted.)
-
EVAP control system pressure sensor
FAIL-SAFE
Not applicable
Confirmation Procedure
Confirmation Procedure
DTC CONFIRMATION PROCEDURE
Note:
Never remove fuel filler cap during DTC confirmation procedure.
-
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at least 10 seconds before conducting the next test.
Do you have CONSULT?
With CONSULT>>GO TO 2.
Without CONSULT>>GO TO 5.
-
PERFORM DTC CONFIRMATION PROCEDURE-1
With CONSULT-
Start the engine and let it idle for least 40 seconds.
Note:
Do not depress accelerator pedal even slightly.
-
Check 1st trip DTC.
Is 1st trip DTC detected?
YES >>Refer to DTC Diagnosis Procedure.
NO >>GO TO 3.
-
-
PERFORM DTC CONFIRMATION PROCEDURE-2
With CONSULT-
Select “EVAP DIAG READY” in “DATA MONITOR” mode of “ENGINE” using CONSULT.
-
Let it idle until “OFF” of “EVAP DIAG READY” changes to “ON”.
Note:
It will take at most 2 hours until “OFF” of “EVAP DIAG READY” changes to “ON”.
-
Turn ignition switch OFF and wait at least 90 minutes.
Note:
Never turn ignition switch ON during 90 minutes.
-
Turn ignition switch ON.
-
Select “EVAP LEAK DIAG” in “DATA MONITOR” mode of “ENGINE” using CONSULT.
-
Check that “EVAP LEAK DIAG” indication.
Which is displayed on CONSULT?
“CMPLT”>>GO TO 4.
“YET”>>-
Perform DTC CONFIRMATION PROCEDURE again.
-
GO TO 1.
-
-
PERFORM DTC CONFIRMATION PROCEDURE-3
With CONSULTCheck 1st trip DTC.
Is 1st trip DTC detected?
YES >>Refer to DTC Diagnosis Procedure.
NO-1 >>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2 >>Confirmation after repair: INSPECTION END
-
PERFORM DTC CONFIRMATION PROCEDURE-4
With GST-
Start the engine and let it idle for least 40 seconds.
Note:
Do not depress accelerator pedal even slightly.
-
Check 1st trip DTC.
Is 1st trip DTC detected?
YES >>Refer to DTC Diagnosis Procedure.
NO >>GO TO 6.
-
-
PERFORM DTC CONFIRMATION PROCEDURE-5
With GST-
Let it idle for at least 2 hours.
-
Turn ignition switch OFF and wait at least 90 minutes.
Note:
Never turn ignition switch ON during 90 minutes.
-
Turn ignition switch ON.
-
Check 1st trip DTC.
Is 1st trip DTC detected?
YES >>Refer to DTC Diagnosis Procedure.
NO-1 >>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2 >>Confirmation after repair: INSPECTION END
-
Dtc Diagnosis Procedure
DTC Diagnosis Procedure
-
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
-
Turn ignition switch OFF.
-
Disconnect EVAP control system pressure sensor harness connector.
-
Check sensor harness connector for water.
Water should not exist.
Is the inspection result normal?
YES >>GO TO 2.
NO >>Repair or replace harness connector.
-
-
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY
-
Turn ignition switch ON.
-
Check the voltage between EVAP control system pressure sensor harness connector and ground.
+
−
Voltage
(Approx.)
EVAP control system pressure sensor
Connector
Terminal
B65
3
Ground
5 V
Is the inspection result normal?
YES >>GO TO 4.
NO >>GO TO 3.
-
-
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B65
3
E16
135
Existed
-
Also check harness for short to ground and to power.
Is the inspection result normal?
YES >>Perform the trouble diagnosis for power supply circuit.
NO >>Repair or replace malfunctioning part.
-
-
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B65
1
E16
158
Existed
-
Also check harness for short to power.
Is the inspection result normal?
YES >>GO TO 5.
NO >>Repair or replace malfunctioning part.
-
-
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR SIGNAL CIRCUIT
-
Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B65
2
E16
131
Existed
-
Also check harness for short to ground and to power.
Is the inspection result normal?
YES >>GO TO 6.
NO >>Repair or replace malfunctioning part.
-
-
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Check the EVAP control system pressure sensor. Refer to Component Inspection.
Is the inspection result normal?
YES >>INSPECTION END
NO >>Replace EVAP control system pressure sensor.
Other materials:
Unit Disassembly and Assembly
Rear Combination Lamp (body Side)
Exploded View
Exploded View
1.
Rear combination lamp
2.
Stop/tail lamp bulb
...
Exterior. Symptom Diagnosis. Squeak and Rattle Trouble Diagnoses
Squeak and Rattle Trouble Diagnoses
Work Flow
Work Flow
CUSTOMER INTERVIEW
Interview the customer if possible, to determine
the conditions that exist when the noise occurs. Use the Diagnostic
Worksheet during the interview to document the facts and conditions
when the noise occu ...
P0014 Evt Control
Dtc Description
DTC Description
DTC DETECTION LOGIC
DTC
CONSULT screen terms
(Trouble diagnosis
content)
DTC detection
condition
...