Dtc Description
DTC DETECTION LOGIC
|
DTC |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition |
|
|
P0193 |
FUEL PRES SEN/CIRC (Fuel rail pressure sensor “A” circuit high) |
Diagnosis condition |
Engine running at idle |
|
Signal (terminal) |
Fuel rail pressure sensor signal |
||
|
Threshold |
Signal voltage from the fuel rail pressure sensor remains at more than 4.06 V |
||
|
Diagnosis delay time |
5 seconds or more |
||
POSSIBLE CAUSE
Harness or connectors
Fuel rail pressure sensor circuit is open or shorted.
Sensor power supply 2 is shorted.
Fuel rail pressure sensor
Each sensor, connected with sensor power supply 2 circuit
FAIL-SAFE
Not applicable
Confirmation Procedure
CHECK DTC PRIORITY
If DTC P0193 is displayed with DTC P0088 or P0090, first perform the trouble diagnosis for DTC P0088 or P0090.
Is other DTC detected?
YES >>Perform diagnosis of applicable.
DTC P0088: Refer to DTC Description.
DTC P0090: Refer to DTC Description.
GO TO 2.
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is 11 V or more at idle.
>>GO TO 3.
PERFORM DTC CONFIRMATION PROCEDURE
Start engine and let it idle for at least 1 minute.
Check DTC or 1st trip DTC.
Is DTC or 1st trip DTC detected?
YES >>Proceed to DTC Diagnosis Procedure.
NO-1 >>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2 >>Confirmation after repair: INSPECTION END
Dtc Diagnosis Procedure
Turning the ignition switch ON with FRP sensor harness connector disconnected causes ECM to detect DTC P0190. Be sure to erase the DTC when the diagnosis procedure.
CHECK DTC PRIORITY
If DTC P0193 is displayed with DTC P0088 or P0090, first perform the trouble diagnosis for DTC P0088 or P0090.
Is other DTC detected?
YES >>Perform diagnosis of applicable.
DTC P0088: Refer to DTC Description.
DTC P0090: Refer to DTC Description.
GO TO 2.
CHECK FUEL RAIL PRESSURE (FRP) SENSOR POWER SUPPLY-1
Turn ignition switch OFF.
Disconnect FRP sensor harness connector.
Turn ignition switch ON.
Check the voltage between FRP sensor harness connector terminals.
|
FRP sensor |
Voltage (Approx.) |
||
|---|---|---|---|
|
Connector |
+ |
− |
|
|
Terminal |
|||
|
F101 |
1 |
3 |
5 V |
Is inspection result normal?
YES >>GO TO 8.
NO >>GO TO 3.
CHECK FRP SENSOR POWER SUPPLY-2
Check the voltage between FRP sensor harness connector and ground.
|
+ |
− |
Voltage (Approx.) |
|
|---|---|---|---|
|
FRP sensor |
|||
|
Connector |
Terminal |
||
|
F101 |
1 |
Ground |
5 V |
Is inspection result normal?
YES >>GO TO 6.
NO >>GO TO 4.
CHECK FRP SENSOR POWER SUPPLY CIRCUIT
Turn ignition switch OFF.
Disconnect ECM harness connector.
Check the continuity between FRP sensor harness connector and ECM harness connector.
|
FRP sensor |
ECM |
Continuity |
||
|---|---|---|---|---|
|
Connector |
Terminal |
Connector |
Terminal |
|
|
F101 |
1 |
F24 |
43 |
Existed |
Is inspection result normal?
YES >>GO TO 5.
NO >>Repair or replace malfunctioning part.
CHECK SENSOR POWER SUPPLY 2 CIRCUIT
Refer to Diagnosis Procedure.
Is inspection result normal?
YES >>Perform the trouble diagnosis for ECM power supply circuit. Refer to Diagnosis Procedure.
NO >>Replace malfunctioning part.
CHECK FRP SENSOR GROUND CIRCUIT
Turn ignition switch OFF.
Disconnect ECM harness connector
Check the continuity between FRP sensor harness connector and ECM harness connector.
|
FRP sensor |
ECM |
Continuity |
||
|---|---|---|---|---|
|
Connector |
Terminal |
Connector |
Terminal |
|
|
F101 |
3 |
F24 |
45 |
Existed |
Also check harness for short to power.
Is inspection result normal?
YES >>GO TO 7.
NO >>Repair or replace malfunctioning part.
CHECK ECM GROUND CIRCUIT
Check the continuity between ECM harness connector and the ground.
|
ECM |
— |
Continuity |
|
|---|---|---|---|
|
Connector |
Terminal |
||
|
F24 |
5 |
Ground |
Existed |
|
65 |
|||
|
F25 |
69 |
||
|
E16 |
157 |
||
|
159 |
|||
|
162 |
|||
Also check harness for short to power.
Is inspection result normal?
YES >>INSPECTION END
NO >>Repair or replace malfunctioning part.
CHECK FRP SENSOR SIGNAL CIRCUIT
Turn ignition switch OFF.
Disconnect ECM harness connector.
Check the continuity between FRP sensor harness connector and ECM harness connector.
|
FRP sensor |
ECM |
Continuity |
||
|---|---|---|---|---|
|
Connector |
Terminal |
Connector |
Terminal |
|
|
F101 |
2 |
F24 |
44 |
Existed |
Also check harness for short to ground and short to power.
Is inspection result normal?
YES >>GO TO 9.
NO >>Repair or replace malfunctioning part.
CHECK FRP SENSOR
Refer to Component Inspection.
Is inspection result normal?
YES >>INSPECTION END
NO >>Replace FRP sensor. Refer to Exploded View.
P0192 Frp Sensor
P0196 Eot SensorMass Air Flow Sensor
Component Inspection
Component Inspection
CHECK MASS AIR FLOW (MAF)
SENSOR-1
With CONSULT
Turn ignition switch OFF.
Reconnect all harness connectors
disconnected.
Start the en ...
Engine compartment check locations
2.0L 4 cylinder (MR20DD engine model)
Engine oil filler cap
Brake and clutch (if so equipped) fluid reservoir
Fuse and relay box
Battery
Air cleaner
Engine oil dipstick
Drive belt location
Windshield-washer fluid reservoir
Engine coolant reservoir
NOTE:
Your Nissan Sentra ...
G Sensor
Exploded View
G sensor
Bracket
Vehicle front
NВ·m (kg-m, ft-lb)
NВ·m (kg-m, in-lb)
Removal and Installation
WARNING:
Do not leave any objects (screwdrivers, tools, etc.) on the seat during
seat repair. It can lead to personal
injury if the side air bag module should acc ...