Dtc Description
DTC DETECTION LOGIC
|
DTC |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition |
|
|
P0192 |
FUEL PRES SEN/CIRC (Fuel rail pressure sensor “A” circuit low) |
Diagnosis condition |
Engine running at idle |
|
Signal (terminal) |
Fuel rail pressure sensor signal |
||
|
Threshold |
Signal voltage from the fuel rail pressure sensor remains at less than 0.37 V |
||
|
Diagnosis delay time |
5 seconds or more |
||
POSSIBLE CAUSE
Harness or connectors
Fuel rail pressure sensor circuit is open or shorted.
Sensor power supply 2 is shorted.
Fuel rail pressure sensor
Each sensor, connected with sensor power supply 2 circuit
FAIL-SAFE
Not applicable
Confirmation Procedure
CHECK DTC PRIORITY
If DTC P0193 is displayed with DTC P0088 or P0090, first perform the trouble diagnosis for DTC P0088 or P0090.
Is other DTC detected?
YES >>Perform diagnosis of applicable.
DTC P0088: Refer to DTC Description.
DTC P0090: Refer to DTC Description.
GO TO 2.
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is 11 V or more at idle.
>>GO TO 3.
PERFORM DTC CONFIRMATION PROCEDURE
Start engine and let it idle for at least 1 minute.
Check DTC or 1st trip DTC.
Is DTC or 1st trip DTC detected?
YES >>Proceed to DTC Diagnosis Procedure.
NO-1 >>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2 >>Confirmation after repair: INSPECTION END
Dtc Diagnosis Procedure
Turning the ignition switch ON with FRP sensor harness connector disconnected causes ECM to detect DTC P0190. Be sure to erase the DTC when the diagnosis procedure.
CHECK DTC PRIORITY
If DTC P0193 is displayed with DTC P0088 or P0090, first perform the trouble diagnosis for DTC P0088 or P0090.
Is other DTC detected?
YES >>Perform diagnosis of applicable.
DTC P0088: Refer to DTC Description.
DTC P0090: Refer to DTC Description.
GO TO 2.
CHECK FUEL RAIL PRESSURE (FRP) SENSOR POWER SUPPLY-1
Turn ignition switch OFF.
Disconnect FRP sensor harness connector.
Turn ignition switch ON.
Check the voltage between FRP sensor harness connector terminals.
|
FRP sensor |
Voltage (Approx.) |
||
|---|---|---|---|
|
Connector |
+ |
− |
|
|
Terminal |
|||
|
F101 |
1 |
3 |
5 V |
Is inspection result normal?
YES >>GO TO 8.
NO >>GO TO 3.
CHECK FRP SENSOR POWER SUPPLY-2
Check the voltage between FRP sensor harness connector and ground.
|
+ |
− |
Voltage (Approx.) |
|
|---|---|---|---|
|
FRP sensor |
|||
|
Connector |
Terminal |
||
|
F101 |
1 |
Ground |
5 V |
Is inspection result normal?
YES >>GO TO 6.
NO >>GO TO 4.
CHECK FRP SENSOR POWER SUPPLY CIRCUIT
Turn ignition switch OFF.
Disconnect ECM harness connector.
Check the continuity between FRP sensor harness connector and ECM harness connector.
|
FRP sensor |
ECM |
Continuity |
||
|---|---|---|---|---|
|
Connector |
Terminal |
Connector |
Terminal |
|
|
F101 |
1 |
F24 |
43 |
Existed |
Is inspection result normal?
YES >>GO TO 5.
NO >>Repair or replace malfunctioning part.
CHECK SENSOR POWER SUPPLY 2 CIRCUIT
Refer to Diagnosis Procedure.
Is inspection result normal?
YES >>Perform the trouble diagnosis for ECM power supply circuit. Refer to Diagnosis Procedure.
NO >>Replace malfunctioning part.
CHECK FRP SENSOR GROUND CIRCUIT
Turn ignition switch OFF.
Disconnect ECM harness connector
Check the continuity between FRP sensor harness connector and ECM harness connector.
|
FRP sensor |
ECM |
Continuity |
||
|---|---|---|---|---|
|
Connector |
Terminal |
Connector |
Terminal |
|
|
F101 |
3 |
F24 |
45 |
Existed |
Also check harness for short to power.
Is inspection result normal?
YES >>GO TO 7.
NO >>Repair or replace malfunctioning part.
CHECK ECM GROUND CIRCUIT
Check the continuity between ECM harness connector and the ground.
|
ECM |
— |
Continuity |
|
|---|---|---|---|
|
Connector |
Terminal |
||
|
F24 |
5 |
Ground |
Existed |
|
65 |
|||
|
F25 |
69 |
||
|
E16 |
157 |
||
|
159 |
|||
|
162 |
|||
Also check harness for short to power.
Is inspection result normal?
YES >>INSPECTION END
NO >>Repair or replace malfunctioning part.
CHECK FRP SENSOR SIGNAL CIRCUIT
Turn ignition switch OFF.
Disconnect ECM harness connector.
Check the continuity between FRP sensor harness connector and ECM harness connector.
|
FRP sensor |
ECM |
Continuity |
||
|---|---|---|---|---|
|
Connector |
Terminal |
Connector |
Terminal |
|
|
F101 |
2 |
F24 |
44 |
Existed |
Also check harness for short to ground and short to power.
Is inspection result normal?
YES >>GO TO 9.
NO >>Repair or replace malfunctioning part.
CHECK FRP SENSOR
Refer to Component Inspection.
Is inspection result normal?
YES >>INSPECTION END
NO >>Replace FRP sensor. Refer to Exploded View.
P0191 Frp Sensor
P0193 Frp SensorRear disc brake
BRAKE PAD
BRAKE PAD : Exploded View
Upper sliding pin bolt
Lower sliding pin bolt
Bushing
Cylinder body
Inner shim cover
Inner shim
Inner pad (with pad wear sensor)
Pad retainer
Torque member
Outer pad
Outer shim
Outer shim cover
Apply rubber grease
Molykote A ...
Trunk
Consult Function (bcm - Trunk)
CONSULT Function (BCM - TRUNK)
BCM
Refer to CONSULT Function (BCM - TRUNK).
...
Brake fluid
Drain and Refill
CAUTION:
Do not spill or splash brake fluid on painted surfaces. Brake
fluid may damage paint. If brake fluid is
splashed on painted areas, wash it away with water immediately.
Prior to repair, turn the ignition switch OFF, disconnect the ABS
actuator and electric uni ...