Nissan Sentra B18 (2020-2025) Service Manual: P0192 Frp Sensor
Dtc Description
DTC Description
DTC DETECTION LOGIC
|
DTC |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition |
|
|
P0192 |
FUEL PRES SEN/CIRC (Fuel rail pressure sensor “A” circuit low) |
Diagnosis condition |
Engine running at idle |
|
Signal (terminal) |
Fuel rail pressure sensor signal |
||
|
Threshold |
Signal voltage from the fuel rail pressure sensor remains at less than 0.37 V |
||
|
Diagnosis delay time |
5 seconds or more |
||
POSSIBLE CAUSE
-
Harness or connectors
-
Fuel rail pressure sensor circuit is open or shorted.
-
Sensor power supply 2 is shorted.
-
-
Fuel rail pressure sensor
-
Each sensor, connected with sensor power supply 2 circuit
FAIL-SAFE
Not applicable
Confirmation Procedure
Confirmation Procedure
-
CHECK DTC PRIORITY
If DTC P0193 is displayed with DTC P0088 or P0090, first perform the trouble diagnosis for DTC P0088 or P0090.
Is other DTC detected?
YES >>Perform diagnosis of applicable.
-
DTC P0088: Refer to DTC Description.
-
DTC P0090: Refer to DTC Description.
GO TO 2.
-
-
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is 11 V or more at idle.
>>GO TO 3.
-
PERFORM DTC CONFIRMATION PROCEDURE
-
Start engine and let it idle for at least 1 minute.
-
Check DTC or 1st trip DTC.
Is DTC or 1st trip DTC detected?
YES >>Proceed to DTC Diagnosis Procedure.
NO-1 >>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2 >>Confirmation after repair: INSPECTION END
-
Dtc Diagnosis Procedure
DTC Diagnosis Procedure
Note:
Turning the ignition switch ON with FRP sensor harness connector disconnected causes ECM to detect DTC P0190. Be sure to erase the DTC when the diagnosis procedure.
-
CHECK DTC PRIORITY
If DTC P0193 is displayed with DTC P0088 or P0090, first perform the trouble diagnosis for DTC P0088 or P0090.
Is other DTC detected?
YES >>Perform diagnosis of applicable.
-
DTC P0088: Refer to DTC Description.
-
DTC P0090: Refer to DTC Description.
GO TO 2.
-
-
CHECK FUEL RAIL PRESSURE (FRP) SENSOR POWER SUPPLY-1
-
Turn ignition switch OFF.
-
Disconnect FRP sensor harness connector.
-
Turn ignition switch ON.
-
Check the voltage between FRP sensor harness connector terminals.
FRP sensor
Voltage
(Approx.)
Connector
+
−
Terminal
F101
1
3
5 V
Is inspection result normal?
YES >>GO TO 8.
NO >>GO TO 3.
-
-
CHECK FRP SENSOR POWER SUPPLY-2
Check the voltage between FRP sensor harness connector and ground.
+
−
Voltage
(Approx.)
FRP sensor
Connector
Terminal
F101
1
Ground
5 V
Is inspection result normal?
YES >>GO TO 6.
NO >>GO TO 4.
-
CHECK FRP SENSOR POWER SUPPLY CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F101
1
F24
43
Existed
Is inspection result normal?
YES >>GO TO 5.
NO >>Repair or replace malfunctioning part.
-
-
CHECK SENSOR POWER SUPPLY 2 CIRCUIT
Refer to Diagnosis Procedure.
Is inspection result normal?
YES >>Perform the trouble diagnosis for ECM power supply circuit. Refer to Diagnosis Procedure.
NO >>Replace malfunctioning part.
-
CHECK FRP SENSOR GROUND CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector
-
Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F101
3
F24
45
Existed
-
Also check harness for short to power.
Is inspection result normal?
YES >>GO TO 7.
NO >>Repair or replace malfunctioning part.
-
-
CHECK ECM GROUND CIRCUIT
-
Check the continuity between ECM harness connector and the ground.
ECM
—
Continuity
Connector
Terminal
F24
5
Ground
Existed
65
F25
69
E16
157
159
162
-
Also check harness for short to power.
Is inspection result normal?
YES >>INSPECTION END
NO >>Repair or replace malfunctioning part.
-
-
CHECK FRP SENSOR SIGNAL CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F101
2
F24
44
Existed
-
Also check harness for short to ground and short to power.
Is inspection result normal?
YES >>GO TO 9.
NO >>Repair or replace malfunctioning part.
-
-
CHECK FRP SENSOR
Refer to Component Inspection.
Is inspection result normal?
YES >>INSPECTION END
NO >>Replace FRP sensor. Refer to Exploded View.
Other materials:
Removal and Installation
Av Control Unit
Exploded View
Exploded View
1.
AV control unit bracket
(LH)
2.
AV control unit
...
Door Lock and Unlock Switch
Driver Side
Component Function Check
Component Function
Check
CHECK FUNCTION
CONSULT
Ignition switch ON.
Select ″CDL LOCK SW″, ″CDL UNLOCK SW″ in ″Data
...
Distance Sensor
Values on the Diagnosis Tool
Values On The Diagnosis Tool
Note:
The following table includes information (items)
inapplicable to this Nissan Sentra vehicle. For information (items) applicable to this
vehicle, refer to CONSULT display items.
...