SYSTEM INITIALIZATION (IF NECESSARY)
If any of the following occur, system initialization must be performed.
Electric power supply to power window switch or motor is interrupted by blown fuse or disconnecting battery cable, etc.
Removal and installation of the regulator assembly.
Removal and installation of the motor from the regulator assembly.
Removal and installation of the harness connector of the power window switch.
Operation of the regulator assembly as a unit.
Removal and installation of the door glass.
Removal and installation of the door glass run.
Window is partly opened and or closed multiple times with out being fully closed.
To perform system initialization, refer to Description.
INSPECT THE FUNCTION OF THE ANTI-PINCH SYSTEM.
To inspect the anti-pinch system, refer to Description.
Removal and Installation
Front RegulatorFront Auxiliary Input Jacks
Removal and Installation
Removal and Installation
REMOVAL
Remove
cluster lid C. Refer to Removal and Installation.
Using a
suitable tool, release pawls on the front auxiliary input jacks
(1), then remove from the front of cluster lid C (2).
...
Precaution
Precaution for Supplemental Restraint System (SRS) "AIR BAG" and "SEAT BELT
PRE-TENSIONER"
The supplemental restraint system such as “air bag” and “seat belt pre-tensioner”,
used along
with a front seat belt, helps to reduce the risk or severity of injur ...
U1010 Control unit (CAN)
Description
Air bag diagnosis sensor performs self-tests on key ON. If CAN communication
failure within control unit is
detected, DTC is set.
DTC Logic
DTC DETECTION LOGIC
CONSULT name
DTC
DTC detecting condition
Repair order
CAN CONTROL UNIT FAILURE
U1010
CAN ...