Diagnosis Procedure
Diagnosis Procedure
The ICC system is not canceled even when the CVT shift lever is shifted to the N position while the ICC system is active.
-
CHECK D RANGE SWITCH
CONSULTCheck if “D RANGE SW” operates normally in “Data Monitor” of “ICC/ADAS 2” with CONSULT.
Is the inspection result normal?
YES >>GO TO 6.
NO >>GO TO 2.
-
PERFORM ALL SELF-DIAGNOSIS ITEMS
CONSULT-
Select “Self Diagnostic Result” mode of “ICC/ADAS 2”.
-
Check if the “U1000-01” is detected in “Self Diagnostic Result” mode of “ICC/ADAS 2”.
Is “U1000-01” detected?
YES >>GO TO 3.
NO >>GO TO 4.
-
-
CAN COMMUNICATIONS INSPECTION
Check the CAN communication and repair or replace malfunctioning parts. Refer to DTC Index.
>>Inspection End.
-
CHECK POSITION SWITCH
Check if “SLCT LVR POSI” operates normally in “Data Monitor” of “TRANSMISSION”.
Is the inspection result normal?
YES >>GO TO 6.
NO >>GO TO 5.
-
PERFORM TCM SELF-DIAGNOSIS
CONSULT-
Select the “Self Diagnostic Result” of “TRANSMISSION”.
-
Repair or replace malfunctioning parts. Refer to DTC Index.
GO TO 7.
-
-
REPLACE ADAS CONTROL UNIT 2
Replace the ADAS control unit 2. Refer to Removal and Installation.
>>GO TO 7.
-
CHECK ICC SYSTEM
CONSULT-
Erase the self-diagnosis results, and then perform “All DTC Reading” again after performing the action test. (Refer to Work Procedure for action test.)
-
Check that the ICC system is normal.
Inspection End.
-
Other materials:
B2f06-11 Back Door/trunk Opener Switch
Dtc Description
DTC Description
DTC DETECTION LOGIC
DTC No.
CONSULT screen items (Trouble
diagnosis content)
DTC detecting condition
...
Rear Window Glass
Exploded View
Exploded View
1.
Spacer
2.
Rear window glass
3.
Adhesive ...
Diagnosis System (adas Control Unit 2)
Diagnosis Description
Diagnosis Description
APPLICATION ITEMS
CONSULT performs the following functions via CAN communication
using ADAS control unit 2.
Diagnosis mode
CGW Status
...