Nissan Sentra B18 (2020-2025) Service Manual: Headlamp (hi) Circuit
Component Function Check
Component Function Check
-
CHECK HEADLAMP (HI) OPERATION
-
CONSULT-
Select “HEADLAMP (HI)” in “Active Test” mode of “IPDM E/R”.
-
Turn lighting switch 2ND.
-
With operating the test item, check that the headlamp (HI) is turned ON.
On
: Headlamp (HI) ON
Off
: Headlamp (HI) OFF
-
Is the inspection result normal?
YES>>Headlamp (HI) circuit is normal.
NO>>Refer to Diagnosis Procedure.
-
Diagnosis Procedure
Diagnosis Procedure
-
CHECK HEADLAMP (HI) BULB
-
Check the headlamp (HI) bulb. Refer to Component Inspection.
Is the inspection result normal?
YES >>GO TO 2.
NO >>Replace corresponding headlamp (HI) bulb. Refer to Bulb Replacement.
-
-
CHECK HEADLAMP (HI) OUTPUT VOLTAGE
-
CONSULT-
Ignition switch ON.
-
Turn lighting switch 2nd.
-
Select “HEADLAMP (HI)” in “Active Test” mode of “IPDM E/R”.
-
With operating the test item, check voltage between IPDM E/R harness connector and ground.
+
-
Test item
Voltage
(Approx.)
IPDM E/R
Connector
Terminal
RH
E48
54
Ground
HEADLAMP (HI)
On
Battery voltage
Off
0V
LH
E44
59
On
Battery voltage
Off
0V
-
Is the inspection result normal?
YES >>GO TO 3.
NO >>GO TO 5.
-
-
CHECK HEADLAMP (HI) POWER SUPPLY CIRCUIT (OPEN)
-
-
Ignition switch OFF.
-
Turn lighting switch OFF.
-
Disconnect IPDM E/R connector and front combination lamp connector.
-
Check continuity between IPDM E/R harness connector and front combination lamp harness connector.
IPDM E/R
Front combination lamp
Continuity
Connector
Terminal
Connector
Terminal
RH
E48
54
E20
3
Yes
LH
E44
59
E21
-
Is the inspection result normal?
YES >>GO TO 4.
NO >>Repair or replace harness.
-
-
CHECK HEADLAMP (HI) GROUND CIRCUIT
-
Check continuity between front combination lamp harness connector and ground.
Front combination lamp
—
Continuity
Connector
Terminal
RH
E20
2
Ground
Yes
LH
E21
Is the inspection result normal?
YES>>Replace corresponding headlamp (HI) bulb. Refer to Bulb Replacement.
NO>>Repair or replace harness.
-
-
CHECK HEADLAMP (HI) POWER SUPPLY CIRCUIT (SHORT TO GROUND)
-
-
Ignition switch OFF.
-
Turn lighting switch OFF.
-
Disconnect IPDM E/R connector, front combination lamp RH connector and front combination lamp LH connector.
-
Check continuity between IPDM E/R harness connector and ground.
IPDM E/R
—
Continuity
Connector
Terminal
RH
E48
54
Ground
No
LH
E44
59
-
Is the inspection result normal?
YES >>Replace IPDM E/R. Refer to Removal and Installation.
NO >>Repair or replace harness.
-
Other materials:
Cooling Fan
Exploded View
Exploded View
1.
Reservoir tank
cap
2.
Reservoir tank
3.
...
Secondary Pressure Solenoid Valve Circuit
Diagnosis Procedure
Diagnosis Procedure
CHECK HARNESS CONNECTOR
Ignition switch OFF.
Check the mating condition of TCM
harness connector and CVT unit harness
connector.
Is the inspect ...
P0420 Three Way Catalyst Function
Dtc Description
DTC Description
The ECM monitors the switching frequency ratio of air fuel ratio
(A/F) sensor 1 and heated oxygen sensor 2.
A three way catalyst (manifold) with high oxygen storage capacity
will indicate a low switching frequency of heated oxygen sensor 2. As oxygen ...