Nissan Sentra B18 (2020-2025) Service Manual: Door Lock Actuator
Driver Side
Component Function Check
Component Function Check
-
CHECK FUNCTION
-
CONSULT-
Select "DOOR LOCK" in "Active Test" mode of "BCM(DOOR LOCK)".
-
Select “ALL LOCK” or “ALL UNLK” to check that it works normally.
-
Is the inspection result normal?
YES>>Door lock actuator is OK.
NO>>Refer to Diagnosis Procedure.
-
Diagnosis Procedure
Diagnosis Procedure
-
CHECK DOOR LOCK ACTUATOR INPUT SIGNAL
-
-
Ignition switch OFF.
-
Disconnect front door lock assembly LH connector.
-
Check voltage between front door lock assembly LH harness connector and ground.
(+)
(–)
Condition
Voltage
(Approx.)
Front door lock assembly LH
Connector
Terminal
D9
1
Ground
Door lock and unlock switch
Unlock
Battery voltage
2
Lock
-
Is the inspection result normal?
YES >>Replace front door lock assembly LH. Refer to Removal and Installation.
NO >>GO TO 2.
-
-
CHECK DOOR LOCK ACTUATOR CIRCUIT
-
-
Disconnect BCM connector and all door lock actuators connectors.
-
Check continuity between BCM harness connector and front door lock assembly LH harness connector.
BCM
Front door lock assembly LH
Continuity
Connector
Terminal
Connector
Terminal
M20
134
D9
1
Yes
142
2
-
Check continuity between BCM harness connector and ground.
BCM
—
Continuity
Connector
Terminal
M20
134
Ground
No
142
-
Is the inspection result normal?
YES >>GO TO 3.
NO >>Repair or replace harness.
-
-
CHECK BCM OUTPUT SIGNAL
-
-
Connect BCM connector.
-
Check voltage between BCM harness connector and ground.
(+)
(–)
Condition
Voltage
(Approx.)
BCM
Connector
Terminal
M20
134
Ground
Door lock and unlock switch
Unlock
Battery voltage
142
Lock
-
Is the inspection result normal?
YES >>Check for internal short of each door lock actuator.
NO >>Replace BCM. Refer to Removal and Installation.
-
Passenger Side
Component Function Check
Component Function Check
-
CHECK FUNCTION
-
CONSULT-
Select "DOOR LOCK" in "Active Test" mode of "BCM(DOOR LOCK)".
-
Select “ALL LOCK” or “ALL UNLK” to check that it works normally.
-
Is the inspection result normal?
YES>>Door lock actuator is OK.
NO>>Refer to Diagnosis Procedure.
-
Diagnosis Procedure
Diagnosis Procedure
-
CHECK DOOR LOCK ACTUATOR INPUT SIGNAL
-
-
Ignition switch OFF.
-
Disconnect front door lock actuator RH connector.
-
Check voltage between front door lock actuator RH harness connector and ground.
(+)
(–)
Condition
Voltage
(Approx.)
Front door lock actuator RH
Connector
Terminal
D107
3
Ground
Door lock and unlock switch
Unlock
Battery voltage
4
Lock
-
Is the inspection result normal?
YES >>Replace front door lock actuator RH. Refer to Removal and Installation.
NO >>GO TO 2.
-
-
CHECK DOOR LOCK ACTUATOR CIRCUIT
-
-
Disconnect BCM connector and all door lock actuators connectors.
-
Check continuity between BCM harness connector and front door lock actuator RH harness connector.
BCM
Front door lock actuator RH
Continuity
Connector
Terminal
Connector
Terminal
M20
132
D107
3
Yes
142
4
-
Check continuity between BCM harness connector and ground.
BCM
—
Continuity
Connector
Terminal
M20
132
Ground
No
142
-
Is the inspection result normal?
YES >>GO TO 3.
NO >>Repair or replace harness.
-
-
CHECK BCM OUTPUT SIGNAL
-
-
Connect BCM connector.
-
Check voltage between BCM harness connector and ground.
(+)
(–)
Condition
Voltage
(Approx.)
BCM
Connector
Terminal
M20
132
Ground
Door lock and unlock switch
Unlock
Battery voltage
142
Lock
-
Is the inspection result normal?
YES >>Check for internal short of each door lock actuator.
NO >>Replace BCM. Refer to Removal and Installation.
-
Rear Lh
Component Function Check
Component Function Check
-
CHECK FUNCTION
-
CONSULT-
Select "DOOR LOCK" in "Active Test" mode of "BCM(DOOR LOCK)".
-
Select “ALL LOCK” or “ALL UNLK” to check that it works normally.
-
Is the inspection result normal?
YES >>Door lock actuator is OK.
NO >>Refer to Diagnosis Procedure.
-
Diagnosis Procedure
Diagnosis Procedure
-
CHECK DOOR LOCK ACTUATOR INPUT SIGNAL
-
-
Ignition switch OFF.
-
Disconnect rear door lock actuator LH connector.
-
Check voltage between rear door lock actuator LH harness connector and ground.
(+)
(–)
Condition
Voltage
(Approx.)
Rear door lock actuator LH
Connector
Terminal
D202
1
Ground
Door lock and unlock switch
Unlock
Battery voltage
2
Lock
-
Is the inspection result normal?
YES >>Replace rear door lock actuator LH. Refer to Removal and Installation.
NO >>GO TO 2.
-
-
CHECK DOOR LOCK ACTUATOR CIRCUIT
-
-
Disconnect BCM connector and rear door lock actuators connectors.
-
Check continuity between BCM harness connector and rear door lock actuator LH harness connector.
BCM
Rear door lock actuator LH
Continuity
Connector
Terminal
Connector
Terminal
M21
155
D202
1
Yes
154
2
-
Check continuity between BCM harness connector and ground.
BCM
—
Continuity
Connector
Terminal
M21
155
Ground
No
154
-
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace harness.
-
-
CHECK BCM OUTPUT SIGNAL
-
-
Connect BCM connector.
-
Check voltage between BCM harness connector and ground.
(+)
(–)
Condition
Voltage
(Approx.)
BCM
Connector
Terminal
M21
155
Ground
Door lock and unlock switch
Unlock
Battery voltage
154
Lock
-
Is the inspection result normal?
YES >>Check for internal short of rear door lock actuators.
NO >>Replace BCM. Refer to Removal and Installation.
-
Rear Rh
Component Function Check
Component Function Check
-
CHECK FUNCTION
-
CONSULT-
Select "DOOR LOCK" in "Active Test" mode of "BCM(DOOR LOCK)".
-
Select “ALL LOCK” or “ALL UNLK” to check that it works normally.
-
Is the inspection result normal?
YES >>Door lock actuator is OK.
NO >>Refer to Diagnosis Procedure.
-
Diagnosis Procedure
Diagnosis Procedure
-
CHECK DOOR LOCK ACTUATOR INPUT SIGNAL
-
-
Ignition switch OFF.
-
Disconnect rear door lock actuator RH connector.
-
Check voltage between rear door lock actuator RH harness connector and ground.
(+)
(–)
Condition
Voltage
(Approx.)
Rear door lock actuator RH
Connector
Terminal
D302
4
Ground
Door lock and unlock switch
Lock
Battery voltage
3
Unlock
-
Is the inspection result normal?
YES >>Replace rear door lock actuator RH. Refer to Removal and Installation.
NO >>GO TO 2.
-
-
CHECK DOOR LOCK ACTUATOR CIRCUIT
-
-
Disconnect BCM connector and rear door lock actuators connectors.
-
Check continuity between BCM harness connector and rear door lock actuator RH harness connector.
BCM
Rear door lock actuator RH
Continuity
Connector
Terminal
Connector
Terminal
M21
155
D302
3
Yes
154
4
-
Check continuity between BCM harness connector and ground.
BCM
—
Continuity
Connector
Terminal
M21
155
Ground
No
154
-
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace harness.
-
-
CHECK BCM OUTPUT SIGNAL
-
-
Connect BCM connector.
-
Check voltage between BCM harness connector and ground.
(+)
(–)
Condition
Voltage
(Approx.)
BCM
Connector
Terminal
M21
155
Ground
Door lock and unlock switch
Unlock
Battery voltage
154
Lock
-
Is the inspection result normal?
YES >>Check for internal short of rear door lock actuators.
NO >>Replace BCM. Refer to Removal and Installation.
-
Other materials:
Starting System. Symptom Diagnosis. Starting System. Symptom Table
Starting System. Symptom Table
Symptom Table
Symptom Table
Symptom
Reference
No normal cranking
Refer to Work Flow (With 165-DSS–5 ...
Body Sealing
Description
Description
The following figure shows the areas which are
sealed at the factory. Sealant which has been applied to these
areas should be smooth and free from cuts or gaps. Care should be
taken not to apply an excess amount of sealant and not to allow
other unaffecte ...
Laser/radar (distance Sensor)
C2580-44 Control Unit
Dtc Description
DTC Description
DTC DETECTION LOGIC
DTC
CONSULT screen terms
(Trouble diagnosis
content)
DTC dete ...