Work Flow
OVERALL SEQUENCE
DETAILED FLOW
INTERVIEW CUSTOMER
Interview the customer to obtain as much information as possible about the conditions and environment under which the malfunction occurred.
GO TO 2.
SYMPTOM CHECK
Verify symptoms.
GO TO 3.
CHECK FOR DTCS
CONSULT
Ignition switch ON.
Select “Self Diagnostic Result” mode of “HVAC”.
Check DTC.
Is any DTC detected?
YES >>GO TO 4.
NO >>GO TO 5.
TROULE DIAGNOSIS BY DTC
Perform the diagnostic procedure for the detected DTC. Refer to DTC Inspection Priority Chart.
GO TO 7.
OPERATION CHECK
Perform the operation check. Refer to Work Procedure.
GO TO 6.
SYMPTOM DIAGNOSIS
Check the symptom diagnosis table. Refer to Diagnosis Chart By Symptom.
GO TO 8.
VERIFY REPAIR
CONSULT
Ignition switch ON.
Select “Self Diagnostic Result” mode of “HVAC”.
Check DTC.
Is any DTC detected?
YES >>GO TO 4.
NO >>GO TO 8.
PERFORM FINAL OPERATION CHECK
Perform the operation check. Refer to Work Procedure.
Does it operate normally?
YES >>Inspection End.
NO >>GO TO 2.
Basic Inspection
Operation InspectionP2238 O2 Sensor 1 Bank 1
Dtc Description
DTC Description
DTC DETECTION LOGIC
To judge malfunctions, the diagnosis checks that the A/F signal
computed by ECM from the A/F sensor 1 signal fluctuates according to fuel
feedback control.
DTC
...
Line Pressure Solenoid Valve Circuit
Diagnosis Procedure
Diagnosis Procedure
CHECK HARNESS CONNECTOR
Ignition switch OFF.
Check the mating condition of TCM
harness connector and CVT unit harness
connector.
Is the inspect ...
Interior room lamp
Removal and installation
Removal
Insert a suitable tool into the gap between the headlining and the
interior room lamp and release the interior
room lamp.
Disconnect the harness connector from the interior room lamp.
Installation
Installation is in the reverse order of removal.