Description
Diagnosis procedure
1.Check seat belt warning lamp
Is the inspection result normal? Yes >> replace combination meter. Refer to mwi-77, "removal and installation".
No >> go to 2.
2.Check seat belt buckle switch (lh) signal circuit
Check the seat belt buckle switch (lh) circuit. Refer to wcs-29, "diagnosis procedure".
Is the inspection result normal? Yes >> go to 3.
No >> repair or replace harness or connector.
3.Check seat belt buckle switch (lh)
Check the seat belt buckle switch (LH). Refer to WCS-30, "Component Inspection".
Is the inspection result normal? YES >> Replace combination meter. Refer to MWI-77, "Removal and Installation".
NO >> Replace seat belt buckle (LH). Refer to SR-32, "Removal and Installation".
Service
Never use electrical test equipment to check SRS circuits unless
instructed to in this Service Manual.
Before servicing the SRS, turn power switch OFF, disconnect battery
negative terminal and wait 3 minutes
or more.
For approximately 3 minutes after the cables are removed, it is stil ...
Wiring diagram
Manual air conditioning system
Wiring Diagram
Manual heater system
Wiring Diagram
...
System initialization
Description
If any of the following operations are performed, the initialization is
necessary for normal operation of power
window system.
Disconnection and connection of battery cable from negative terminal.
When power window main switch replaced.
Electric power supply to power window m ...