Description
Light reminder warning chime does not sound even though headlamp is illuminated.
Diagnosis procedure
1.Check combination meter input signal
Select the data monitor for the meter/m&a and check the buzzer monitor value.
Is the inspection result normal? Yes >> replace combination meter. Refer to mwi-77, "removal and installation".
No >> go to 2.
2.Check front door switch lh signal circuit
Check the front door switch lh signal circuit. Refer to dlk-102, "diagnosis procedure" (with intelligent key system) or dlk-253, "diagnosis procedure" (without intelligent key system).
Is the inspection result normal? Yes >> go to 3.
No >> repair or replace harness or connector.
3.Check front door switch lh
Check front door switch lh. Refer to dlk-103, "component inspection" (with intelligent key system) or dlk- 255, "component inspection" (without intelligent key system).
Is the inspection result normal? Yes >> replace the bcm. Refer to bcs-73, "removal and installation" (with intelligent key system) or bcs-126, "removal and installation" (without intelligent key system).
No >> replace the front door switch lh. Refer to dlk-194, "removal and installation" (with intelligent key system) or dlk-341, "removal and installation" (without intelligent key system).
Abs branch line circuit
Diagnosis procedure
1.Check connector
Turn the ignition switch OFF.
Disconnect the battery cable from the negative terminal.
Check the terminals and connectors of the abs actuator and electric unit
(control unit) for damage, bend
and loose connection (unit side and connector side).
...
Fuel (Regular Unleaded Gasoline Recommended)
Use unleaded regular gasoline with an octane rating of at least 87 AKI
(Anti-Knock Index) number (Research
octane number 91). E-85 fuel (85% fuel ethanol, 15% unleaded gasoline) may only
be used in vehicles specifically
designed for E-85 fuel (i.e. Flexible Fuel Vehicle - FFV models).
CAUTION ...
M&a branch line circuit
Diagnosis procedure
1.Check connector
Turn the ignition switch off.
Disconnect the battery cable from the negative terminal.
Check the terminals and connectors of the combination meter for damage,
bend and loose connection
(unit side and connector side).
Is the inspection result nor ...