Nissan Sentra manuals

Nissan Sentra Service Manual: Tcm branch line circuit

Diagnosis Procedure

1.Check connector

  1. Turn the ignition switch off.
  2. Disconnect the battery cable from the negative terminal.
  3. Check the following terminals and connectors for damage, bend and loose connection (unit side and connector side).

Is the inspection result normal? YES >> GO TO 2.

NO >> Repair the terminal and connector.

2.Check harness for open circuit

  1. Disconnect the connector of tcm.
  2. Check the resistance between the TCM harness connector terminals.

Is the measurement value within the specification?


Is the measurement value within the specification? Yes >> go to 3.

No >> repair the tcm branch line.

3.Check power supply and ground circuit

Check the power supply and the ground circuit of the tcm. Refer to tm-234, "diagnosis procedure".

Is the inspection result normal? Yes (present error)>>replace the tcm. Refer to the tm-263, "removal and installation".

Yes (past error)>>error was detected in the tcm branch line.

No >> repair the power supply and the ground circuit.

Ipdm-e branch line circuit
Diagnosis Procedure 1.Check connector Turn the ignition switch off. Disconnect the battery cable from the negative terminal. Check the terminals and connectors of the ipdm e/r for damage, ben ...

A-bag branch line circuit
Diagnosis procedure Warning: Always observe the following items for preventing accidental activation. Before servicing, turn ignition switch off, disconnect battery negative terminal, and w ...

Other materials:

Precaution for Work
When removing or disassembling each component, be careful not to damage or deform it. If a component may be subject to interference, be sure to protect it with a shop cloth. When removing (disengaging) components with a screwdriver or similar tool, be sure to wrap the component with a ...

Basic inspection
Diagnosis and repair work flow Work flow OVERALL SEQUENCE Detailed flow 1.Get information for symptom Get detailed information from the customer about the symptom (the condition and the environment when the incident/malfunction occurs) Check operation condition of the function tha ...

P0444, P0445 EVAP Canister purge volume control solenoid valve
DTC Logic DTC DETECTION LOGIC DTC No. CONSULT screen terms (Trouble diagnosis content) DTC detecting condition Possible cause P0444 PURG VOLUME CONT/V (Evaporative emission system purge control valve circuit open) An excessively low voltage signal is sent to ...

В© 2014-2019 Copyright www.nisentra.com