Diagnosis procedure
1.Check connector
Is the inspection result normal? Yes >> go to 2.
No >> repair the terminal and connector.
2.Check harness for open circuit
Is the measurement value within the specification? Yes >> go to 3.
No >> repair the ipdm e/r branch line.
3.Check power supply and ground circuit
Check the power supply and the ground circuit of the IPDM E/R. Refer to the following.
Is the inspection result normal? Yes (present error)>>replace the ipdm e/r. Refer to the following.
Yes (past error)>>error was detected in the ipdm e/r branch line.
No >> repair the power supply and the ground circuit.
M&a branch line circuit
Diagnosis procedure
1.Check connector
Turn the ignition switch off.
Disconnect the battery cable from the negative terminal.
Check the terminals and connectors of the combination meter for damage,
bend and loose connection
(unit side and connector side).
Is the inspection result nor ...
Service data and specifications
Wheel Bearing
Drive Shaft
Drive Shaft Specifications
*: Always check with the Parts Department for the latest parts information.
Dynamic Damper Specifications
...
Brake warning lamp
Component Function Check
1.CHECK BRAKE WARNING LAMP FUNCTION (1)
Check that brake warning lamp in combination meter turns ON for
approximately 2 seconds after ignition
switch is turned ON.
Is the inspection result normal?
YES >> GO TO 2.
NO >> Proceed to diagnosis procedure. ...