Component Function Check
1.CHECK VDC OFF SWITCH OPERATION
Check that VDC OFF indicator lamp in combination meter turns ON/OFF when VDC OFF switch is operated.
Is the inspection result normal? YES >> Inspection End.
NO >> Proceed to diagnosis procedure. Refer to BRC-92, "Diagnosis Procedure".
Diagnosis Procedure
Regarding Wiring Diagram information, refer to BRC-44, "Wiring Diagram".
1.CONNECTOR INSPECTION
Turn ignition switch OFF.
Disconnect ABS actuator and electric unit (control unit) and VDC OFF switch connectors.
Check connectors and terminals for deformation, disconnection, looseness or damage.
Is the inspection result normal? YES >> GO TO 2.
NO >> Repair or replace as necessary.
2.CHECK VDC OFF SWITCH
Check VDC OFF switch. Refer to BRC-93, "Component Inspection".
Is the inspection result normal? YES >> GO TO 3.
NO >> Replace VDC OFF switch. Refer to BRC-112, "Removal and Installation".
3.Check VDC OFF Switch signal
With CONSULT.
Connect ABS actuator and electric unit (control unit) and VDC OFF switch connectors.
Turn ignition switch ON.
In “DATA MONITOR” select “OFF SW” and check VDC OFF switch signal.
Is the inspection result normal? YES >> Refer to BRC-51, "Work Flow".
NO >> GO TO 4.
4.Check VDC OFF Switch circuit
Turn ignition switch OFF.
Disconnect ABS actuator and electric unit (control unit) and VDC OFF switch connectors.
Check continuity between ABS actuator and electric unit (control unit) connector E33 terminal 15 and VDC OFF switch connector M64 terminal 6.
Check continuity between ABS actuator and electric unit (control unit) connector terminal E33 terminal 15 and ground.
Is the inspection result normal? YES >> GO TO 5.
NO >> Repair or replace malfunctioning components.
5.Check vdc off switch ground circuit
Check continuity between VDC OFF switch connector M64 terminal 8 and ground.
Is the inspection result normal? YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC-110, "Removal and Installation".
NO >> Repair or replace malfunctioning components.
Component Inspection
1.Check vdc off switch
Turn ignition switch OFF.
Disconnect VDC OFF switch connector.
Check continuity between terminals of VDC OFF switch connector.
Is the inspection result normal? YES >> Inspection End.
NO >> Replace VDC OFF switch. Refer to BRC-112, "Removal and Installation".
Throttle valve closed position
learning
Description
Throttle Valve Closed Position Learning is a function of ECM to learn the
fully closed position of the throttle
valve by monitoring the throttle position sensor output signal. It must be
performed each time the harness connector
of the electric throttle control actuator or ECM is ...
P0715 Input speed sensor A
DTC Logic
DTC DETECTION LOGIC
DTC
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
Possible causes
P0715
INPUT SPEED SENSOR A
(Input/Turbine Speed Sensor
A Circuit)
The primary speed sensor value is less than
150 r ...
Basic inspection
Diagnosis and repair work flow
Work flow
Overall sequence
Detailed flow
1.Get information for symptom
Get detailed information from the customer about the symptom (the
condition and the environment when
the incident/malfunction occurs).
Check operation condition of the component o ...