Component Function Check
1.CHECK ABS WARNING LAMP FUNCTION
Check that ABS warning lamp in combination meter turns ON for approximately 2 seconds after ignition switch is turned ON.
Is the inspection result normal? YES >> Inspection End.
NO >> Proceed to diagnosis procedure. Refer to BRC-94, "Diagnosis Procedure".
Diagnosis Procedure
1.PERFORM THE SELF-DIAGNOSIS
With CONSULT.
Perform self diagnostic result.
Are any DTCs detected? YES >> Refer to BRC-43, "DTC Index".
NO >> GO TO 2.
2.CHECK COMBINATION METER
Check if indication and operation of combination meter are normal. Refer to MWI-8, "METER SYSTEM : System Description".
Is the inspection result normal? YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC-110, "Removal and Installation".
NO >> Replace combination meter. Refer to MWI-77, "Removal and Installation".
Filament
Inspection and Repair
Inspection
When measuring voltage, wrap tin foil around the top of the negative
probe. Then press the foil against the wire with your finger.
Attach probe circuit tester (in Volt range) to middle portion of
each filament.
If a filament is burned out ...
Cylinder block
Exploded View
Cylinder block
Block heater (for Canada)
Top ring
Second ring
Oil ring
Piston
Piston pin
Snap ring
Connecting rod
Connecting rod bearing (upper)
Connecting rod bearing (lower)
Crankshaft key
Connecting rod cap
Connecting rod cap bolt
Main bearing ca ...
Precaution for Harness Repair
Solder the repair part, and wrap it with tape. [Twisted wire
fray
must be 110 mm (4.33 in) or less.]
Do not bypass the repair point with wire. (If it is
bypassed, the turnout
point cannot be separated and the twisted wire characteristics
are lost.)
...