Nissan Sentra manuals

Nissan Sentra Service Manual: Symptom diagnosis

The eco mode indicator lamp does not turn on

Description

The ECO mode indicator lamp does not turn ON when the ECO mode switch is operated.

Diagnosis Procedure

1.Perform combination meter on board diagnosis

Perform combination meter on board diagnosis. Refer to MWI-16, "Description".

Is the check result normal? YES >> GO TO 2.

NO >> Replace combination meter. Refer to MWI-77, "Removal and Installation".

2.Check dtc (tcm)

With consultv


  1. Start the engine.
  2. Check “self diagnostic results” in “transmission”.

Is any DTC detected? YES >> Check DTC detected item. Refer to TM-126, "DTC Index".

NO >> GO TO 3.

3.Check dtc (ecm)

Check “self diagnostic results” in “engine”. With consult


Check “self diagnostic results” in “engine”.

Is any dtc detected? Yes >> check dtc detected item. Refer to ec-94, "dtc index".

No >> go to 4.

4.Check dtc (combination meter)

Check “self diagnostic results” in “meter/m&a”. With consult


Check “self diagnostic results” in “meter/m&a”.

Is any dtc detected? Yes >> check dtc detected item. Refer to mwi-26, "dtc index".

No >> go to 5.

5.Check combination meter input/output signal

  With consult


  1. Select “data monitor” in “meter/m&a”.
  2. Select “eco mode ind”.
  3. Check that “ECO MODE IND” turns ON/OFF when ECO mode switch is operated. Refer to MWI-20, "Reference Value".

Is any DTC detected? YES >> Replace combination meter. Refer to MWI-77, "Removal and Installation".

NO >> GO TO 6.

6.Check eco mode switch circuit

Check eco mode switch circuit. Refer to dms-34, "diagnosis procedure".

Is any dtc detected? Yes >> inspection end

No >> repair or replace malfunctioning parts.

Dtc/circuit diagnosis
Eco mode switch Component function check 1. Check eco mode switch operation Turn ignition switch ON. Check ECO mode indicator lamp turns ON/OFF on combination meter when turn ECO mode swit ...

Removal and installation
Eco mode switch Removal and installation Removal Remove instrument lower panel LH. Refer to IP-21, "Removal and Installation". Remove ECO mode switch. Installation Installatio ...

Other materials:

Power windows do not operate with power window main switch
Diagnosis Procedure 1.Check bcm power supply and ground circuit Check bcm power supply and ground circuit. Refer to bcs-67, "diagnosis procedure" (with intelligent key) or bcs-120, "diagnosis procedure" (without intelligent key). Is the inspection result normal? Yes & ...

Rear window glass
Exploded View Rear window glass Spacer Rubber dam Body side outer Headlining Roof panel Trunk lid Adhesive 12 mm (0.5 in) 7 mm (0.3 in) 2.0 mm (0.08 in) 3 mm (0.1 in) Removal and Installation REMOVAL Partially remove the rear of the headlining (rear edge). R ...

Rear window defogger and door mirror defoggers do not operate
Diagnosis procedure Regarding Wiring Diagram information, refer to DEF-20, "Wiring Diagram". 1. Check rear window defogger switch Check rear window defogger switch. Refer to def-30, "component function check". Is the inspection result normal? Yes >> go to 2. No ...