Diagnosis Procedure
1.CHECK COMBINATION METER POWER SUPPLY AND GROUND CIRCUIT
Check combination meter unit power supply and ground circuit. Refer to MWI-52, "COMBINATION METER : Diagnosis Procedure".
Is the inspection result normal? YES >> GO TO 2.
NO >> Repair or replace the malfunctioning parts.
2.CHECK HARNESS CONNECTOR
Check the harness connector.
Is the inspection result normal? YES >> GO TO 3.
NO >> Replace harness connectors.
3.CHECK WIRING HARNESS
Check the wiring harness externals.
Is the inspection result normal? YES >> GO TO 4.
NO >> Replace wiring harness.
4.CHECK AIR BAG DIAGNOSIS SENSOR UNIT
Disconnect air bag diagnosis sensor unit connector and turn ignition switch ON.
Does air bag warning lamp turn ON? YES >> Replace air bag diagnosis sensor unit. Refer to SR-28, "Removal and Installation".
NO >> Replace combination meter. Refer to MWI-77, "Removal and Installation".
SRS Air bag warning lamp does not turn OFF
Seat belt warning systemEps branch line circuit
Diagnosis procedure
1.Check connector
Turn the ignition switch off.
Disconnect the battery cable from the negative terminal.
Check the terminals and connectors of the eps control unit for damage,
bend and loose connection (unit
side and connector side).
Is the inspection result norm ...
DTC/circuit diagnosis
U1000 CAN COMM CIRCUIT
Description
CAN (Controller Area Network) is a serial communication system for real time
application. It is an on-vehicle
multiplex communication system with high data communication speed and excellent
error detection ability.
Many electronic control units are equip ...
P0452 EVAP Control system pressure sensor
DTC Logic
DTC DETECTION LOGIC
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detecting condition
Possible cause
P0452
EVAP SYS PRES SEN
(Evaporative emission system
pressure sensor/switch low)
An excessively low voltage from the
sensor is se ...