Diagnosis procedure
1. Check rear window defogger power supply and ground circuit
Check rear window defogger power supply and ground circuit.
Refer to DEF-32, "Component Function Check".
Is the inspection result normal? YES >> Refer to GI-39, "Intermittent Incident".
NO >> Repair or replace the malfunctioning parts.
Trunk room lamp
Removal and Installation
Warning:
Do not touch bulb while it is lit or right after being turned off.
Burning may result.
Caution:
Do not touch glass surface of the bulb with bare hands or allow oil or
grease to get on it to prevent
damage to bulb.
Release the tab (b) to open the lens.
...
Strg branch line circuit
Diagnosis procedure
1.Check connector
Turn the ignition switch off.
Disconnect the battery cable from the negative terminal.
Check the terminals and connectors of the steering angle sensor for
damage, bend and loose connection
(unit side and connector side).
Is the inspection result ...
Basic inspection
Diagnosis and repair work flow
Work flow
Detailed flow
1.Obtain information about symptom
Interview the customer to obtain as much information as possible about the
conditions and environment under
which the malfunction occurs.
>> GO TO 2.