Diagnosis Procedure
CHECK FUSE
Turn ignition switch OFF.
Pull out 5 A fuse (No. 91) from IPDM E/R.
Check that 5 A fuse is not blowing.
Is the fuse blown (open)?
YES >>Replace the fuse after repairing the applicable circuit.
NO >>GO TO 2.
CHECK FUSIBLE LINK
Turn ignition switch OFF.
Check that the following fusible link is not blowing.
|
Fusible link No. |
Capacity |
|---|---|
|
F/L-I |
40A |
Is the fusible link blown (open)?
YES >>Replace the fusible link after repairing the applicable circuit.
NO >>GO TO 3.
CHECK GROUND CONNECTION
Check ground connection E9 and E15. Refer to Ground Inspection in Circuit Inspection.
Is the inspection result normal?
YES >>GO TO 4.
NO >>Repair or replace error-detected parts.
CHECK ELECTRIC INTAKE VALVE TIMING CONTROL MODULE GROUND CIRCUIT
Disconnect electric intake valve timing control module harness connectors.
Check the continuity between electric intake valve timing control module harness connector and ground.
|
Electric intake valve timing control module |
— |
Continuity |
|
|---|---|---|---|
|
Connector |
Terminal |
||
|
F80 |
43 |
Ground |
Existed |
Also check harness for short to power.
Is the inspection result normal?
YES >>GO TO 5.
NO >>Repair or replace error-detected parts.
CHECK ELECTRIC INTAKE VALVE TIMING CONTROL MODULE POWER SUPPLY
Reconnect electric intake valve timing control module harness connectors.
Check the voltage between electric intake valve timing control module harness connector terminals as follows.
|
Electric intake valve timing control module |
Voltage |
||
|---|---|---|---|
|
Connector |
+ |
− |
|
|
Terminal |
|||
|
F80 |
47 |
43 |
Battery voltage |
Is the inspection result normal?
YES >>GO TO 6.
NO >>Perform trouble diagnosis for power supply circuit.
CHECK IGNITION SWITCH SIGNAL
Check the voltage between electric intake valve timing control module harness connectors as follows.
|
Electric intake valve timing control module |
Condition |
Voltage |
||
|---|---|---|---|---|
|
+ |
− |
|||
|
Connector |
Terminal |
Terminal |
||
|
F80 |
39 |
43 |
Ignition switch: ON |
Battery voltage |
|
Ignition switch: OFF |
0 V |
|||
Is the inspection result normal?
YES >>Check intermittent incident. Refer to Intermittent Incident.
NO >>GO TO 7.
CHECK IGNITION SWITCH SIGNAL
Turn ignition switch OFF.
Disconnect electric intake valve timing control module harness connectors.
Disconnect IPDM E/R harness connector.
Check the continuity between IPDM E/R harness connector and electric intake valve timing control module harness connector.
|
IPDM E/R |
Electric intake valve timing control module |
Continuity |
||
|---|---|---|---|---|
|
Connector |
Terminal |
Connector |
Terminal |
|
|
E43 |
19 |
F80 |
39 |
Existed |
Also check harness for short to power and short to ground.
Is the inspection result normal?
YES >>Perform trouble diagnosis for power supply circuit.
NO >>Repair or replace error-detected parts.
Power Supply and Ground Circuit (ecm)
Refrigerant Pressure SensorDiagnosis Procedure
Diagnosis Procedure
CHECK INTELLIGENT KEY SYSTEM SYMPTOM
TABLE
Check Intelligent Key system symptom table.
Refer to Diagnosis Procedure.
>>
GO TO
2.
CHECK INTELLIGENT KEY OUTPUT ...
Dtc Diagnosis Procedure
DTC Diagnosis Procedure
PERFORM SELF DIAGNOSTIC RESULT
CONSULT
Ignition switch OFF to ON.
Erase "Self Diagnostic Result" mode of "EPS/DAST
3".
...
Seat Belt Warning Chime
Seat Belt Warning Chime
Seat Belt Warning
Chime
SYSTEM DIAGRAM
DESCRIPTION
Seat belt warning chime warns the driver that driver
seat belt, passenger seat belt, or rear seat belts are not fastened.
WARNING OPERATION CONDITIONS
Front Seat Belts
Combination meter operates seat ...