Diagnosis Procedure
CHECK FUSE
Check that the following fuses are not blown:
|
Terminal No. |
Signal name |
Fuse No. |
Capacity |
|---|---|---|---|
|
1 |
Battery power supply |
35 |
10 A |
|
10 |
Ignition signal |
48 |
10 A |
Are the fuses blown?
YES >>Replace the blown fuse after repairing the affected circuit.
NO >>GO TO 2.
CHECK POWER SUPPLY CIRCUIT
Ignition switch OFF.
Disconnect TCU connector .
Check voltage between TCU connector and ground.
|
(+) |
(-) |
Condition |
Voltage (Approx.) |
|
|---|---|---|---|---|
|
TCU |
||||
|
Connector |
Terminal |
|||
|
M160 |
1 |
Ground |
Ignition switch: OFF |
Battery voltage |
|
10 |
Ignition switch: ON |
|||
Is the inspection result normal?
YES >>GO TO 3.
NO >>Repair or replace harness or connectors.
CHECK GROUND CIRCUIT
Ignition switch OFF.
Check continuity between TCU connector and ground.
|
TCU |
— |
Continuity |
|
|---|---|---|---|
|
Connector |
Terminal |
||
|
M160 |
28 |
Ground |
Yes |
|
29 |
|||
Is the inspection result normal?
YES>>Inspection End.
NO>>Repair or replace harness or connectors.
U0079 Control Module Comm Bus G OffDiagnosis system (bcm) (without intelligent key system)
Common item
COMMON ITEM : CONSULT Function (BCM - COMMON ITEM)
APPLICATION ITEM
CONSULT performs the following functions via CAN communication with BCM.
Direct Diagnostic Mode
Description
ECU identification
The BCM part number is displayed.
Self Diagnostic Result
...
Diagnosis Procedure
Diagnosis Procedure
CHECK TRUNK ROOM LAMP SWITCH INPUT SIGNAL
Ignition switch OFF.
Check voltage between trunk lid opener assembly
(ajar switch) harness connector and ground.
...
Chime Does Not Sound
Diagnosis Procedure
Diagnosis Procedure
The warning chime may not sound in some cases when there is a
short distance between vehicles. Some examples are:
When the Nissan Sentra vehicles are traveling at the same speed and the
distance between vehicles is not changing.
...