Nissan Sentra manuals

Nissan Sentra Service Manual: P060A ECM

DTC Logic

DTC DETECTION LOGIC

DTC No.

CONSULT screen terms (Trouble diagnosis content)

DTC detecting condition

Possible cause

P060A CONTROL MODULE (Internal control module monitoring processor performance) ECM internal monitoring processor is malfunctioning. ECM

DTC CONFIRMATION PROCEDURE

1.PRECONDITIONING

  1. Turn ignition switch OFF and wait at least 10 seconds.
  2. Turn ignition switch ON.
  3. Turn ignition switch OFF and wait at least 10 seconds.

TESTING CONDITION:

Before performing the following procedure, confirm that battery voltage is 11 V or more with ignition switch ON.

>> GO TO 2.

2.PERFORM DTC CONFIRMATION PROCEDURE

  1. Start engine and wait at least 10 seconds
  2. Turn ignition switch OFF and wait at least 10 seconds.
  3. Repeat step 1 and 2 for 5 times.
  4. Turn ignition switch ON.
  5. Check 1st trip DTC.

Is 1st trip DTC detected? YES >> Proceed to EC-351, "Diagnosis Procedure".

NO >> INSPECTION END

Diagnosis Procedure

1.PERFORM DTC CONFIRMATION PROCEDURE

  1. Turn ignition switch ON.
  2. Erase DTC.
  3. Perform DTC confirmation procedure. Refer to EC-351, "DTC Logic".

Is the 1st trip DTC P060A displayed again? YES >> Replace ECM. Refer to EC-485, "Removal and Installation".

NO >> INSPECTION END

P0607 ECM
DTC Logic DTC DETECTION LOGIC DTC No. CONSULT screen terms (Trouble diagnosis content) DTC detecting condition Possible cause P0607 ECM (Control module performance) ...

P060B ECM
DTC Logic DTC DETECTION LOGIC DTC No. CONSULT screen terms (Trouble diagnosis content) DTC detecting condition Possible cause P060B CONTROL MODULE (Internal control ...

Other materials:

Trunk lid
Trunk lid assembly Trunk lid assembly : exploded view Trunk lid hinge LH/RH Torsion bar LH/RH Torsion bar clips Trunk lid finisher (if equipped) Emergency release handle Emergency release handle clip Emergency release handle cable Trunk lid lock Trunk lid bumpers License lam ...

Wiring diagram
Eco mode system Wiring Diagram ...

Interior room lamp control circuit
Description Controls each interior room lamp (ground side) by pwm signal. Note: Pwm signal control period is approximately 250 hz (in the gradual brightening/dimming). Component function check Caution: Before performing the diagnosis, check that the following are normal. Interior room l ...