Diagnosis Procedure
CHECK COMBINATION METER INPUT SIGNAL
Ignition switch ON.
Check voltage between the following terminals of the illumination control switch.
|
Illumination control switch |
Condition |
Voltage (Approx.) |
||
|---|---|---|---|---|
|
Connector |
Terminals |
|||
|
(+) |
(−) |
|||
|
M66 |
6 |
4 |
When illumination control switch (+) is pressed |
0 V |
|
Other than the above |
5 V |
|||
|
7 |
When illumination control switch (−) is pressed |
0 V |
||
|
Other than the above |
5 V |
|||
Is the inspection result normal?
YES>>Inspection End.
NO>>GO TO 2.
CHECK ILLUMINATION CONTROL SWITCH SIGNAL CIRCUIT
Ignition switch OFF.
Disconnect combination meter harness connector and illumination control switch harness connector.
Check continuity between combination meter harness connector and illumination control switch harness connector.
|
Combination meter |
Illumination control switch |
Continuity |
||
|---|---|---|---|---|
|
Connector |
Terminal |
Connector |
Terminal |
|
|
M24 |
32 |
M66 |
4 |
Yes |
|
31 |
7 |
|||
|
25 |
6 |
|||
Check continuity between combination meter harness connector and ground.
|
Combination meter |
— |
Continuity |
|
|---|---|---|---|
|
Connector |
Terminal |
||
|
M24 |
32 |
Ground |
No |
|
31 |
|||
|
25 |
|||
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace harness or connector.
CHECK ILLUMINATION CONTROL SWITCH
Check illumination control switch. Refer to Component Inspection.
Is the inspection result normal?
YES>>Replace combination meter. Refer to Removal and Installation.
NO>>Replace illumination control switch. Refer to Removal and Installation.
Component Inspection
CHECK ILLUMINATION CONTROL SWITCH
Ignition switch OFF.
Disconnect illumination control switch harness connector.
Check continuity between the following terminals of the illumination control switch:
|
Illumination control switch |
Condition |
Continuity |
|
|---|---|---|---|
|
Terminals |
|||
|
6 |
4 |
When illumination control switch (+) is pressed |
Yes |
|
Other than the above |
No |
||
|
7 |
When illumination control switch (−) is pressed |
Yes |
|
|
Other than the above |
No |
||
Is the inspection result normal?
YES >>Inspection End.
NO >>Replace illumination control switch. Refer to Removal and Installation.
Power Supply and Ground Circuit
Fuel Level Sensor Signal CircuitBoth Side Headlamps (hi) Are Not Turned on
Diagnosis Procedure
Diagnosis Procedure
Both side headlamps (HI) are not turned ON when
setting to the lighting switch HI or PASS.
COMBINATION SWITCH INSPECTION
Check combination switch. Refer to Symptom Table.
Is the inspection ...
Dtc Confirmation Procedure
DTC Confirmation Procedure
PERFORM DTC CONFIRMATION
PROCEDURE
CONSULT
Ignition switch ON.
Ignition switch OFF and wait at least 30
seconds.
...
C1111 PUMP MOTOR
DTC Logic
DTC DETECTION LOGIC
DTC
Display Item
Malfunction detected condition
Possible causes
C1111
PUMP MOTOR
When a malfunction is detected in motor or motor
relay.
When a low pressure malfunction is detected in accumulator.
When a malfunction ...