Nissan Sentra B18 (2020-2025) Service Manual: Heated Oxygen Sensor 2 Heater

Component Inspection

Component Inspection

  1. CHECK HEATED OXYGEN SENSOR 2 HEATER

    1. Turn ignition switch OFF.

    2. Disconnect heated oxygen sensor 2 harness connector.

    3. Check resistance between heated oxygen sensor 2 terminals as follows.

      Heated oxygen sensor 2

      Condition

      Resistance

      +

      Terminal

      4

      3

      Temperature

      25°C (77°F)

      5.4 – 7.3 Ω

      1

      2

      Not existed

      3

      4

      4

      1

      2

    Is the inspection result normal?

    YES >>

    INSPECTION END

    NO >>

    Replace malfunctioning heated oxygen sensor 2.

    Fuel Tank Vacuum Relief Valve
    Component Inspection Component Inspection CHECK FUEL FILLER CAP Turn ignition switch OFF. Remove fuel filler cap. Wipe clean valve housing. Install fuel filler cap adapter (comm...
    High Pressure Fuel Pump
    Component Function Check Component Function Check CHECK HIGH PRESSURE FUEL PUMP FUNCTION With CONSULT Start engine. Select “FUEL PRES SEN V” in “DATA MONITOR” mode of ...

    Other materials:

    Sonar System. Basic Inspection
    Diagnosis and Repair Work Flow. Work Flow Work Flow Work Flow OVERALL SEQUENCE Reference 1: Refer to CONSULT Function. Reference 2: Refer to DTC Index. Reference 3: Refer to Symptom Table. DETAILED FLOW INTERVIEW AND SYMPTO ...

    P0315 Ckp Sensor (pos)
    Dtc Description DTC Description DTC DETECTION LOGIC DTC CONSULT screen terms (Trouble diagnosis content) DTC detection condition ...

    Tire pressure
    Tire Pressure Monitoring System (TPMS) WARNING Radio waves emitted by the Tire Pressure Monitoring System (TPMS) may adversely affect certain types of electronic medical equipment. Individuals who use a pacemaker or other implanted medical devices should contact the medical equipment manufact ...