Nissan Sentra B18 (2020-2025) Service Manual: Heated Oxygen Sensor 2 Heater
Component Inspection
Component Inspection
-
CHECK HEATED OXYGEN SENSOR 2 HEATER
-
Turn ignition switch OFF.
-
Disconnect heated oxygen sensor 2 harness connector.
-
Check resistance between heated oxygen sensor 2 terminals as follows.
Heated oxygen sensor 2
Condition
Resistance
+
−
Terminal
4
3
Temperature
25°C (77°F)
5.4 – 7.3 Ω
1
2
Not existed
3
4
4
1
2
Is the inspection result normal?
YES >>INSPECTION END
NO >>Replace malfunctioning heated oxygen sensor 2.
-
Other materials:
P2096 A/f Sensor 1
Dtc Description
DTC Description
DTC DETECTION LOGIC
DTC
CONSULT screen terms
(Trouble diagnosis
content)
DTC detection
condition
...
Roof. Basic Inspection
Diagnosis and Repair Work Flow. Work Flow
Work Flow
Work Flow
OVERALL SEQUENCE
DETAILED FLOW
INTERVIEW CUSTOMER
Interview the customer to obtain as much information
as possible about the conditions and environment under which the malfuncti ...
P0452 Evap Control System Pressure Sensor
Dtc Description
DTC Description
DTC DETECTION LOGIC
DTC
CONSULT screen terms
(Trouble diagnosis
content)
DTC detection
condition
...