Nissan Sentra manuals

Nissan Sentra B18 (2020-2025) Service Manual: Evap Canister

Evap Canister : Periodic Maintenance

EVAP CANISTER : Periodic Maintenance

CAUTION:

Note:

WITH CONSULT

Install EVAP service port adapter [commercial service tool: (NI-41413-OBD)] and pressure pump to EVAP service port. Note:

If vacuum delay valve does not have EVAP service port, remove vacuum delay valve and install EVAP service port [commercial service tool: (Part No. 149393S500)] instead.

Turn ignition switch ON.

Select the “EVAP SYSTEM CLOSE” of “WORK SUPPORT” mode with CONSULT.

Touch “START”. A bar graph (Pressure indicating display) will appear on the screen.

Apply positive pressure to the EVAP system until the pressure indicator reaches the middle of the bar graph.

Remove EVAP service port adapter [commercial service tool: (NI-41413-OBD)] and hose with pressure pump.

Locate the leak using a leak detector (commercial service tool). Refer to System Description.

WITHOUT CONSULT

Install EVAP service port adapter [commercial service tool: (NI-41413-OBD)] and pressure pump to EVAP service port. Note:

If vacuum delay valve does not have EVAP service port, remove vacuum delay valve and install EVAP service port [commercial service tool: (Part No. 149393S500)] instead.

Apply battery voltage between the terminals of EVAP canister vent control valve to make a closed EVAP system.

To locate the leak, deliver positive pressure to the EVAP system until pressure gauge points reach 1.38 to 2.76 kPa (0.014 to 0.028 kg/cm2, 0.2 to 0.4 psi).

Remove EVAP service port adapter [commercial service tool: (NI-41413-OBD)] and hose with pressure pump.

Locate the leak using a leak detector (commercial service tool). Refer to System Description.

Evaporative Emission System
Evaporative Emission System : Inspection EVAPORATIVE EMISSION SYSTEM : Inspection CHECK EVAP CANISTER Block port (B). Blow air in ...

Positive Crankcase Ventilation
Positive Crankcase Ventilation : Periodic Maintenance POSITIVE CRANKCASE VENTILATION : Periodic Maintenance Start engine and let it idle. Replace PCV valve from the rocker cover. Refer t ...

Other materials:

Can communication circuit
Diagnosis procedure 1.Connector inspection Turn the ignition switch OFF. Disconnect the battery cable from the negative terminal. Disconnect all the unit connectors on can communication system. Check terminals and connectors for damage, bend and loose connection. Is the inspection resu ...

Removal and Installation
Removal and Installation REMOVAL CAUTION: Before servicing, turn the ignition switch OFF, disconnect both battery terminals and wait at least three minutes. Do not use air or electric tools when removing or installing the ...

With Washer Level Switch
Exploded View Exploded View 1. Washer tank inlet 2. Washer tank A. W ...

© 2014-2026 Copyright www.nisentra.com