Nissan Sentra B18 (2020-2025) Service Manual: B Terminal Circuit. Diagnosis Procedure
Diagnosis Procedure
Diagnosis Procedure
“B” terminal circuit supplies power to charge the battery and to operate the vehicles electrical system.
-
CHECK “B” TERMINAL CONNECTION
-
-
Ignition switch OFF.
-
Check if “B” terminal is clean and tight.
-
Is the inspection result normal?
YES >>GO TO 2.
NO >>Repair terminal “B” connection. Confirm repair by performing system test using the 165-DSS-5000P. Refer to applicable Instruction Manual for proper testing procedures.
-
-
CHECK “B” TERMINAL CIRCUIT
-
Check voltage between generator “B” terminal and ground.
(+)
(-)
Voltage
(Approx.)
Generator
Connector
Terminal
F14
1
Ground
Battery voltage
Is the inspection result normal?
YES >>GO TO 3.
NO >>Check harness for open between generator and fusible link.
-
-
CHECK “B” TERMINAL CONNECTION (VOLTAGE DROP TEST)
-
-
Start engine, then engine running at idle and warm.
-
Check voltage between battery positive terminal and generator connector “B” terminal.
(+)
(-)
Voltage
(Approx.)
Generator
Connector
Terminal
F14
1
Battery positive terminal
Less than 0.2 V
-
Is the inspection result normal?
YES>>“B” terminal circuit is normal. Refer to Work Flow (With 165-DSS-5000P) or Work Flow (Without 165-DSS-5000P).
NO>>Check harness between battery and generator for continuity.
-
Other materials:
Instrument Panel. Symptom Diagnosis. Squeak and Rattle Trouble Diagnoses
Squeak and Rattle Trouble Diagnoses
Work Flow
Work Flow
CUSTOMER INTERVIEW
Interview the customer if possible, to determine
the conditions that exist when the noise occurs. Use the Diagnostic
Worksheet during the interview to document the facts and conditions
when the noise occu ...
Service Data and Specifications (sds). Service Data and Specifications (sds)
Service Data and Specifications (sds)
Bulb Specifications
Bulb Specifications
Item
Wattage (W)*
Bulb No.
Front combi ...
Decel G Sensor Calibration
Description
Description
TCM stores calibration data (inherent characteristic value) of
decel G sensor to provide accurate control.
Therefore, it is required to perform calibration of decel G sensor
after the following work is performed.
Removing/ installing ABS actuator ...