The eco mode indicator lamp does not turn on
Description
The ECO mode indicator lamp does not turn ON when the ECO mode switch is operated.
Diagnosis Procedure
1.Perform combination meter on board diagnosis
Perform combination meter on board diagnosis. Refer to MWI-16, "Description".
Is the check result normal? YES >> GO TO 2.
NO >> Replace combination meter. Refer to MWI-77, "Removal and Installation".
2.Check dtc (tcm)
With consultv
Is any DTC detected? YES >> Check DTC detected item. Refer to TM-126, "DTC Index".
NO >> GO TO 3.
3.Check dtc (ecm)
With consult
Check “self diagnostic results” in “engine”.
Is any dtc detected? Yes >> check dtc detected item. Refer to ec-94, "dtc index".
No >> go to 4.
4.Check dtc (combination meter)
With consult
Check “self diagnostic results” in “meter/m&a”.
Is any dtc detected? Yes >> check dtc detected item. Refer to mwi-26, "dtc index".
No >> go to 5.
5.Check combination meter input/output signal
With consult
Is any DTC detected? YES >> Replace combination meter. Refer to MWI-77, "Removal and Installation".
NO >> GO TO 6.
6.Check eco mode switch circuit
Check eco mode switch circuit. Refer to dms-34, "diagnosis procedure".
Is any dtc detected? Yes >> inspection end
No >> repair or replace malfunctioning parts.
P1078 EVT Control position sensor
DTC Logic
DTC DETECTION LOGIC
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detecting condition
Possible cause
P1078
EXH TIM SEN/CIRC-B1
(Exhaust valve timing control
position sensor circuit
bank 1)
An excessively high or low voltage from
...
S connector circuit
Description
The starter motor magnetic switch is supplied with power when the ignition
switch is turned to the START position
while the selector lever is in the P (Park) or N (Neutral) position (CVT Models)
or the clutch pedal is
depressed (M/T Models).
Diagnosis Procedure
Regarding Wiring ...
Controls
Fan control dial
The fan control dial turns the fan on and off, and
controls fan speed.
Air flow control buttons
The air flow control buttons allow you to select
the air flow outlets.
MAX — Air flows from center and side
A/Cvents with maximum cooling.
— Air flows from center and side
v ...