Component Function Check
1.CHECK SLIP INDICATOR LAMP FUNCTION
Check that slip indicator lamp in combination meter turns ON for approximately 2 seconds after ignition switch is turned ON.
Is the inspection result normal? YES >> Inspection End.
NO >> Proceed to diagnosis procedure. Refer to BRC-97, "Diagnosis Procedure".
Diagnosis Procedure
1.PERFORM THE SELF-DIAGNOSIS
With CONSULT
Perform self diagnostic result.
Are any DTCs detected? YES >> Refer to BRC-43, "DTC Index".
NO >> GO TO 2.
2.CHECK COMBINATION METER
Check if indication and operation of combination meter are normal. Refer to MWI-8, "METER SYSTEM : System Description".
Is the inspection result normal? YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC-110, "Removal and Installation".
NO >> Replace combination meter. Refer to MWI-77, "Removal and Installation".
VDC OFF Indicator lampOperating tips
When the engine coolant temperature and
outside air temperature are low, the air flow
from the foot outlets may not operate for a
maximum of 150 seconds. However, this is
not a malfunction. After the coolant temperature
warms up, air flow from the foot outlets
will operate normally.
...
Basic inspection
Diagnosis and repair workflow
Work Flow
OVERALL SEQUENCE
DETAILED FLOW
1.OBTAIN INFORMATION ABOUT SYMPTOM
Interview the customer to obtain as much information as possible about the
conditions and environment under
which the malfunction occurred.
>> GO TO 2.
2.CHECK SYMPTOM
...
A-bag branch line circuit
Diagnosis procedure
Warning:
Always observe the following items for preventing accidental
activation.
Before servicing, turn ignition switch off, disconnect battery
negative terminal, and wait 3 minutes
or more. (To discharge backup capacitor.)
Never use unspecified tester or other me ...