Nissan Sentra manuals

Nissan Sentra Service Manual: Slip indicator lamp

Component Function Check

1.CHECK SLIP INDICATOR LAMP FUNCTION

Check that slip indicator lamp in combination meter turns ON for approximately 2 seconds after ignition switch is turned ON.

Is the inspection result normal? YES >> Inspection End.

NO >> Proceed to diagnosis procedure. Refer to BRC-97, "Diagnosis Procedure".

Diagnosis Procedure

1.PERFORM THE SELF-DIAGNOSIS

Perform self diagnostic result. With CONSULT


Perform self diagnostic result.

Are any DTCs detected? YES >> Refer to BRC-43, "DTC Index".

NO >> GO TO 2.

2.CHECK COMBINATION METER

Check if indication and operation of combination meter are normal. Refer to MWI-8, "METER SYSTEM : System Description".

Is the inspection result normal? YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC-110, "Removal and Installation".

NO >> Replace combination meter. Refer to MWI-77, "Removal and Installation".

VDC OFF Indicator lamp
Description Component Function Check 1.CHECK VDC OFF INDICATOR LAMP FUNCTION Check that VDC OFF indicator lamp in combination meter turns ON for approximately 2 seconds after ignition switch ...

Symptom diagnosis
...

Other materials:

Operating tips
When the engine coolant temperature and outside air temperature are low, the air flow from the foot outlets may not operate for a maximum of 150 seconds. However, this is not a malfunction. After the coolant temperature warms up, air flow from the foot outlets will operate normally. ...

Basic inspection
Diagnosis and repair workflow Work Flow OVERALL SEQUENCE DETAILED FLOW 1.OBTAIN INFORMATION ABOUT SYMPTOM Interview the customer to obtain as much information as possible about the conditions and environment under which the malfunction occurred. >> GO TO 2. 2.CHECK SYMPTOM ...

A-bag branch line circuit
Diagnosis procedure Warning: Always observe the following items for preventing accidental activation. Before servicing, turn ignition switch off, disconnect battery negative terminal, and wait 3 minutes or more. (To discharge backup capacitor.) Never use unspecified tester or other me ...