Diagnosis Procedure
1. Perform initialization procedure
Perform initialization procedure.
Refer to rf-18, "additional service when replacing control unit : special repair requirement".
Is the inspection result normal? Yes >> inspection end.
No >> perform basic inspection. Refer to rf-16, "work flow".
Auto operation does not operate
Does not stop fully-open or fullyclosed
positionP2004 Intake manifold runner control valve
DTC Logic
DTC DETECTION LOGIC
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detecting condition
Possible cause
P2004
TUMBLE CONT/V
(Intake manifold runner control
stuck open bank 1)
The target angle of intake manifold runner
control valve c ...
Precaution for work
When removing or disassembling each component, be careful not to damage
or deform it. If a component
may be subject to interference, be sure to protect it with a shop cloth.
When removing (disengaging) components with a screwdriver or similar
tool, be sure to wrap the component
with a ...
M&A branch line circuit
Diagnosis procedure
1.Check connector
Turn the ignition switch off.
Disconnect the battery cable from the negative terminal.
Check the terminals and connectors of the combination meter for damage,
bend and loose connection
(unit side and connector side).
Is the inspection result nor ...