Nissan Sentra manuals

Nissan Sentra Service Manual: Auto operation does not operate but manual operate normally (driver side)

Nissan Sentra Service Manual / Body exterior, doors, roof & vehicle security / Power window control system / Symptom diagnosis / Auto operation does not operate but manual operate normally (driver side)

Diagnosis Procedure

1.PERFORM INITIALIZATION PROCEDURE

Initialization procedure is executed and operation is confirmed.

Refer to PWC-29, "Work Procedure".

Is the inspection result normal? YES >> INSPECTION END

NO >> GO TO 2.

2.CHECK ENCODER CIRCUIT

Check encoder circuit.

Refer to PWC-50, "DRIVER SIDE : Diagnosis Procedure".

Is the inspection result normal? YES >> GO TO 3.

NO >> Repair or replace the malfunctioning parts.

3.REPLACE POWER WINDOW MAIN SWITCH

Is the result normal? YES >> INSPECTION END

NO >> Check intermittent incident. Refer to GI-39, "Intermittent Incident".

Rear rh side power window does not operate
When both power window main switch and rear power window switch RH are operated When both power window main switch and rear power window switch rh are operated : diagnosis procedure 1.CHECK REAR ...

Anti-pinch system does not operate normally (driver side)
Diagnosis Procedure 1.CHECK POWER WINDOW AUTO OPERATION Check AUTO operation when anti-pinch function does not operate. Refer to PWC-67, "Diagnosis Procedure". Is the inspection resu ...

Other materials:

Av branch line circuit
Diagnosis Procedure 1.Check connector Turn the ignition switch off. Disconnect the battery cable from the negative terminal. Check the terminals and connectors of the av control unit for damage, bend and loose connection (unit side and connector side). Is the inspection result norma ...

Precaution for Supplemental Restraint System (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER"
The Supplemental Restraint System such as “AIR BAG” and “SEAT BELT PRE-TENSIONER”, used along with a front seat belt, helps to reduce the risk or severity of injury to the driver and front passenger for certain types of collision. Information necessary to service the system ...

M&a branch line circuit
Diagnosis procedure 1.Check connector Turn the ignition switch off. Disconnect the battery cable from the negative terminal. Check the terminals and connectors of the combination meter for damage, bend and loose connection (unit side and connector side). Is the inspection result nor ...

© 2014-2025 Copyright www.nisentra.com