Symptom

Noise source

Probable cause

Corrective action

Unusual noise from A/C compressor when A/C is ON.

Inside of A/C compressor

Wear, breakage or clogging of foreign material in inner parts.

Check A/C compressor oil. Refer to Inspection.

Magnet clutch

Contact of clutch disc with pulley.

Check clearance between clutch disc and pulley.

A/C compressor body

Loosened A/C compressor mounting bolts.

Check bolts for tightness. Refer to Exploded View.

Unusual noise from cooler piping.

Cooler piping (pipe and flexible hose)

Improper installation of clip and bracket.

Check the installation condition of the cooler piping. Refer to Exploded View.

Unusual noise from expansion valve when A/C is ON.

Expansion valve

Shortage of refrigerant.

  • Check for leakage.

  • Collect all refrigerant, evacuate refrigerant cycle again, and then refill it with the specified amount of refrigerant.

Wear, breakage or clogging of foreign material in inner parts.

Eliminate foreign material from expansion valve or replace it.

Unusual noise from belt.

—

Loosened belt

Check belt tension. Refer to Inspection.

Internal A/C compressor parts get locked

Replace A/C compressor. Refer to Removal and Installation.

Noise
...

Heater & Air Conditioning System :: Periodic Maintenance
...

Other materials:

P1551, P1552 Battery current sensor
DTC Logic DTC DETECTION LOGIC DTC No. CONSULT screen terms (Trouble diagnosis content) DTC detecting condition Possible cause P1551 BAT CURRENT SENSOR (Battery current sensor) An excessively low voltage from the sensor is sent to ECM. Harness or ...

Heated seats (if so equipped)
The front seats are warmed by built-in heaters. Start the engine. Push the LO or HI position of the switch, as desired. The indicator light in the switch will illuminate. The heater is controlled by a thermostat, automatically turning the heater on and off. The indicator light ...

Evaporative emission system
Inspection EVAP CANISTER 1.CHECK EVAP CANISTER Block port (B). Blow air into port (A) and check that it flows freely out of port (C). Release blocked port (B). Apply vacuum pressure to port (B) and check that vacuum pressure exists at the ports (A) and (C). Block port (A) and (B). ...