Dtc Description
DTC DETECTION LOGIC
|
DTC |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition |
|
|
P0447 |
VENT CONTROL VALVE (Evaporative emission system vent control circuit open) |
Diagnosis condition |
Engine running at idle |
|
Signal (terminal) |
EVAP canister vent control valve signal |
||
|
Threshold |
An improper voltage signal is sent to ECM through EVAP canister vent control valve |
||
|
Diagnosis delay time |
— |
||
POSSIBLE CAUSE
Harness or connectors (EVAP canister vent control valve circuit is open or shorted.)
EVAP canister vent control valve
FAIL-SAFE
Not applicable
Confirmation Procedure
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm battery voltage is more than 11 V at idle.
>>GO TO 2.
PERFORM DTC CONFIRMATION PROCEDURE
Start the engine and wait at least 8 seconds.
Check 1st trip DTC.
Is 1st trip DTC detected?
YES >>Proceed to DTC Diagnosis Procedure.
NO-1 >>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2 >>Confirmation after repair: INSPECTION END
Dtc Diagnosis Procedure
INSPECTION START
Do you have CONSULT?
YES >>GO TO 2.
NO >>GO TO 3.
CHECK EVAP CANISTER VENT CONTROL VALVE CIRCUIT
With CONSULT
Turn ignition switch OFF and then turn ON.
Select “VENT CONTROL/V” in “ACTIVE TEST” mode of “ENGINE” using CONSULT.
Touch “ON/OFF” on CONSULT screen.
Check for operating sound of the valve.
|
Clicking sound should be heard. |
Is the inspection result normal?
YES >>GO TO 7.
NO >>GO TO 3.
CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY
Turn ignition switch OFF.
Disconnect EVAP canister vent control valve harness connector.
Turn ignition switch ON.
Check the voltage between EVAP canister vent control valve harness connector and ground.
|
+ |
− |
Voltage |
|
|---|---|---|---|
|
EVAP canister vent control valve |
|||
|
Connector |
Terminal |
||
|
B17 |
1 |
Ground |
Battery voltage |
Is the inspection result normal?
YES >>GO TO 5.
NO >>GO TO 4.
CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
Turn ignition switch OFF.
Disconnect IPDM E/R harness connector.
Check the continuity between EVAP canister vent control valve harness connector and IPDM E/R harness connector.
|
EVAP canister vent control valve |
IPDM E/R |
Continuity |
||
|---|---|---|---|---|
|
Connector |
Terminal |
Connector |
Terminal |
|
|
B17 |
1 |
F96 |
75 |
Existed |
Also check harness for short to ground.
Is the inspection result normal?
YES >>Perform the trouble diagnosis for power supply circuit.
NO >>Repair or replace malfunctioning part.
CHECK EVAP CANISTER VENT CONTROL VALVE OUTPUT SIGNAL CIRCUIT
Turn ignition switch OFF.
Disconnect ECM harness connector.
Check the continuity between EVAP canister vent control valve harness connector and ECM harness connector.
|
EVAP canister vent control valve |
ECM |
Continuity |
||
|---|---|---|---|---|
|
Connector |
Terminal |
Connector |
Terminal |
|
|
B17 |
2 |
E16 |
151 |
Existed |
Also check harness for short to power.
Is the inspection result normal?
YES >>GO TO 6.
NO >>Repair or replace malfunctioning part.
CHECK RUBBER TUBE FOR CLOGGING
Disconnect rubber tube connected to EVAP canister vent control valve.
Check the rubber tube for clogging.
Is the inspection result normal?
YES >>GO TO 7.
NO >>Clean the rubber tube using an air blower.
CHECK EVAP CANISTER VENT CONTROL VALVE
Check the EVAP canister vent control valve. Refer to Component Inspection.
Is the inspection result normal?
YES >>INSPECTION END
NO >>Replace EVAP canister vent control valve. Refer to Exploded View.
P0448 Evap Canister Vent Control ValveDoes Not Restart After the Idle Start/stop System Is Activated
Diagnosis Procedure
Diagnosis Procedure
CHECK SYMPTOM
Check the symptoms.
A start/stop indicator lamp turned on, and did an
engine perform a stall at the time of restart from a idle start/stop
system?
YES >>
GO TO
2.
NO > ...
Precautions for Refrigerant System Service
Precautions
For Refrigerant System Service
GENERAL REFRIGERANT PRECAUTION
Warning:
Do not breathe A/C refrigerant and oil vapor or
mist. Exposure may irritate eyes, nose and throat. Remove HFO-1234yf
(R-1234yf) from the A/C system, using certified s ...
Can communication circuit
Diagnosis procedure
1.Connector inspection
Turn the ignition switch OFF.
Disconnect the battery cable from the negative terminal.
Disconnect all the unit connectors on can communication system.
Check terminals and connectors for damage, bend and loose connection.