Component Function Check
SYMPTOM: Insufficient cooling
INSPECTION FLOW
CONFIRM SYMPTOM BY PERFORMING OPERATION CHECK - TEMPERATURE DECREASE
Press the A/C switch.
Turn temperature control dial counterclockwise to maximum cold.
Check for cold air at discharge air outlets.
Can a symptom be duplicated?
YES>>GO TO 3.
NO>>GO TO 2.
CHECK FOR ANY SYMPTOMS
Perform a complete operational check and check for any symptoms. Refer to Work Procedure.
Does another symptom exist?
YES>>Refer to Symptom Table.
NO>>System OK.
CHECK FOR SERVICE BULLETINS
Check for any service bulletins.
GO TO 4.
CHECK DRIVE BELTS
Check A/C compressor belt tension. Refer to Inspection.
Is the inspection result normal?
YES>>GO TO 5.
NO>>Replace A/C compressor belt. Refer to Removal and Installation.
CHECK AIR MIX DOOR MOTOR OPERATION
Check and verify air mix door mechanism for smooth operation.
Does air mix door operate correctly?
YES>>GO TO 6.
NO>>Check air mix door motor circuit. Refer to Diagnosis Procedure.
CHECK COOLING FAN MOTOR OPERATION
Check and verify cooling fan motor for smooth operation.
Does cooling fan motor operation correctly?
YES>>GO TO 7.
NO>>Check cooling fan motor. Refer to Component Function Check.
CHECK RECOVERY/RECYCLING EQUIPMENT BEFORE USAGE
Check recovery/recycling equipment before connecting to Nissan Sentra vehicle. Verify there is no pressure in the recovery/recycling equipment by checking the gauges. If pressure exists, recover refrigerant from equipment lines.
GO TO 8.
CHECK REFRIGERANT PURITY
Connect recovery/recycling equipment to Nissan Sentra vehicle.
Confirm refrigerant purity in supply tank using recovery/recycling and refrigerant identifier.
Is the inspection result normal?
YES>>GO TO 9.
NO>>Check contaminated refrigerant. Refer to Description.
CHECK REFRIGERANT PRESSURE
Check refrigerant pressure with manifold gauge connected. Refer to Inspection.
Is the inspection result normal?
YES>>Perform diagnostic work flow. Refer to Workflow.
NO>>GO TO 10.
CHECK FOR EVAPORATOR FREEZE UP
Start engine and run A/C. Check for evaporator freeze up.
Does evaporator freeze up?
YES>>Perform diagnostic work flow. Refer Workflow.
NO>>GO TO 11.
CHECK AIR DUCTS
Check ducts for air leaks.
Is the inspection result normal?
YES>>System OK.
NO>>Repair air leaks.
Heater and Air Conditioning System Control Symptoms
Insufficient HeatingDiagnosis system (BCM)
Common item
Common item : consult function (bcm - common item)
APPLICATION ITEM
CONSULT performs the following functions via CAN communication with BCM.
SYSTEM APPLICATION
BCM can perform the following functions.
Intelligent key
Intelligent key : consult function (bcm - intelligent ke ...
P062f Ecm
Dtc Description
DTC Description
DTC DETECTION LOGIC
DTC
CONSULT screen terms
(Trouble diagnosis
content)
DTC detection
conditi ...
Dtc Diagnosis Procedure
DTC Diagnosis Procedure
REPLACE FRONT POWER WINDOW MOTOR
LH
Replace front power window motor LH. Refer to Removal and Installation.
Perform DTC confirmation procedure. Refer to Confirm ...