Factory-style information for owners and repair work

Nissan Sentra techinfo

Find Nissan Sentra owner information, maintenance instructions, technical references, service procedures and useful repair pages in one clean online library.

Nissan Sentra B18 (2020-2025) Service Manual: Exhaust Valve Timing Control Solenoid Valve

Component Inspection

Component Inspection

  1. CHECK EXHAUST VALVE TIMING (EVT) CONTROL SOLENOID VALVE-1

    1. Turn ignition switch OFF.

    2. Disconnect EVT control solenoid valve harness connector.

    3. Check the resistance between EVT control solenoid valve terminals as per the following.

      EVT control solenoid valve

      Condition

      Resistance

      Terminal

      1

      2

      Temperature

      20°C (68°F)

      6.7 – 7.7 Ω

    4. Check the resistance between EVT control solenoid valve terminal and solenoid valve body.

      EVT control solenoid valve

      —

      Resistance

      Terminal

      1

      Solenoid valve body

      Not existed

      2

    Is the inspection result normal?

    YES >>

    GO TO 2.

    NO >>

    Replace EVT control solenoid valve. Refer to Exploded View.

  2. CHECK EVT CONTROL SOLENOID VALVE-2

    1. Remove EVT control solenoid valve. Refer to Exploded View.

    2. Provide battery voltage between EVT control solenoid valve terminals 1 and 2, and then interrupt it. Check that the plunger moves as shown in the figure.

      CAUTION:

      Do not apply battery voltage continuously for 5 seconds or more. Doing so may result in damage to the coil in EVT control solenoid valve.

      Note:

      Always replace O-ring when EVT control solenoid valve is removed.

    Is the inspection result normal?

    YES >>

    INSPECTION END

    NO >>

    Replace EVT control solenoid valve. Refer to Exploded View.

    Evap Control System Pressure Sensor
    Component Inspection Component Inspection CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR Turn ignition switch OFF. Remove EVAP control system pressure sensor with its harness connect...
    Frp Control System
    Component Inspection Component Inspection CHECK HIGH PRESSURE FUEL PUMP-1 Turn ignition switch OFF. Disconnect high pressure fuel pump harness connector. Check the resistance be...

    Other materials:

    Microphone Signal Circuit
    Diagnosis Procedure Diagnosis Procedure CHECK HARNESS BETWEEN AV CONTROL UNIT AND MICROPHONE Ignition switch OFF. Disconnect AV control unit connector and microph ...

    Before Replacing ECM
    SAVE ECM DATA With CONSULT Turn ignition switch OFF. Reconnect all harness connectors disconnected. Turn ignition switch ON. Select “SAVING DATA FOR REPLC ...

    Symptom Diagnosis. The Eco Mode Indicator Lamp Does Not Turn on
    The Eco Mode Indicator Lamp Does Not Turn on Diagnosis Procedure Diagnosis Procedure CHECK ECO MODE OPERATION Ignition switch ON. Check ECO mode indicator turns ON/OFF on combination meter when turn ECO mode switch ...