Description
When replacing ECM, the following procedure must be performed. (For details, refer to EC-135, "Work Procedure".)
PROGRAMMING OPERATION
NOTE:
After replacing with a blank ECM, programming is required to write ECM information. Be sure to follow the procedure to perform the programming.
Work Procedure
1.SAVE ECM DATA
With CONSULT
NOTE:
>> GO TO 2.
2.CHECK ECM PART NUMBER
Check ECM part number to see whether it is blank ECM or not.
NOTE:
Is the ECM a blank ECM? YES >> GO TO 3.
NO >> GO TO 5.
3.SAVE ECM PART NUMBER
Read out the part number from the old ECM and save the number, following the programming instructions.
Refer to CONSULT Operation Manual.
NOTE:
>> GO TO 4.
4.PERFORM ECM PROGRAMMING
After replacing ECM, perform the ECM programming. Refer to CONSULT Operation Manual.
NOTE:
>> GO TO 6.
5.REPLACE ECM
Replace ECM. Refer to EC-485, "Removal and Installation".
>> GO TO 6.
6.PERFORM INITIALIZATION OF IVIS (NATS) SYSTEM AND REGISTRATION OF ALL IVIS (NATS) IGNITION KEY IDS
Refer to SEC-61, "ECM : Work Procedure" (With Intelligent Key System) or SEC-174, "ECM : Work Procedure" (Without Intelligent Key System).
>> GO TO 7.
7.CHECK ECM DATA STATUS
Check if the data is successfully copied from the ECM at Step 1 (before replacement) and saved in CONSULT.
Is the data saved successfully? YES >> GO TO 8.
NO >> GO TO 9.
8.WRITE ECM DATA
With CONSULT
NOTE:
The data saved by “SAVING DATA FOR REPLC CPU” is written to ECM.
>> GO TO 10.
9.PERFORM VIN REGISTRATION
Refer to EC-137, "Work Procedure".
>> GO TO 10.
10.PERFORM ACCELERATOR PEDAL RELEASED POSITION LEARNING
Perform Accelerator Pedal Released Position Learning. Refer to EC-138, "Work Procedure".
>> GO TO 11.
11.PERFORM THROTTLE VALVE CLOSED POSITION LEARNING
Perform Throttle Valve Closed Position Learning. Refer to EC-139, "Work Procedure".
>> GO TO 12.
12.PERFORM IDLE AIR VOLUME LEARNING
Perform Idle Air Volume Learning. Refer to EC-140, "Work Procedure".
>> END
Condenser
Removal and installation
Removal
Remove the rear pillar finisher. Refer to INT-29, "REAR PILLAR FINISHER
: Removal and Installation".
Disconnect the harness connectors (1), remove the condenser
bolt (A) and the condenser (2).
: Front
Installation
Installation is in th ...
Starter motor drive control
STARTER MOTOR DRIVE CONTROL : System Description
SYSTEN DIAGRAM
*1: CVT models
*2: M/T models
INPUT/OUTPUT SIGNAL CHART
Sensor
Input signal to ECM
ECM function
Actuator
Crankshaft position sensor (POS)
Engine speed
Piston position
Starter ...
P0122, P0123 TP Sensor
DTC Logic
DTC DETECTION LOGIC
NOTE:
If DTC P0122 or P0123 is displayed with DTC P0643, first perform the
trouble diagnosis for DTC P0643.
Refer to EC-353, "DTC Logic".
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detecting condition
Possible caus ...