The actual shape of the tools may differ from those illustrated here.


PreparationPrecautions for drive shaft
Observe the following precautions when disassembling and assembling drive
shaft.
Do not disassemble joint sub-assembly because it is non-overhaul parts.
Perform work in a location which is as dust-free as possible.
Clean the parts, before disassembling and assembling.
Prevent the entry o ...
General Precautions
Always use a 12 volt battery as power source.
Do not attempt to disconnect battery cables while engine is
running.
Before connecting or disconnecting the ECM harness connector,
turn ignition switch OFF and disconnect negative battery
cable. Failure to do so may damage the ECM because
...
Battery current sensor
Exploded view
Battery current sensor
Current sensor harness connector
Removal and installation
Removal
Loosen the battery terminal nut and disconnect battery negative
terminal. Refer to PG-50, "Exploded
View".
Disconnect the harness connector from current sensor.
...