Diagnosis procedure
1.Check connector
Is the inspection result normal? Yes >> go to 2.
No >> repair the terminal and connector.
2.Check harness for open circuit
Check the resistance between the data link connector terminals.

Is the measurement value within the specification? Yes (present error)>>check can system type decision again.
Yes (past error)>>error was detected in the data link connector branch line circuit.
No >> repair the data link connector branch line.
A-bag branch line circuit
Eps branch line circuitIllumination control switch signal circuit
Diagnosis procedure
Regarding wiring diagram information, refer to mwi-28, "wiring diagram".
1.Check combination meter input signal
Turn ignition switch on.
Check voltage between the following terminals of the illumination
control switch.
Is the inspection result normal?
...
Removal and installation
ACCELERATOR CONTROL SYSTEM
Exploded View
Accelerator pedal assembly
Brake pedal bracket
Locating hook
Locating pin
Removal and Installation
REMOVAL
Remove instrument lower panel LH. Refer to IP-21, "Removal and
Installation".
Disconnect the harness connector ...
P0451 EVAP Control system pressure sensor
DTC Logic
DTC DETECTION LOGIC
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detecting condition
Possible cause
P0451
EVAP SYS PRES SEN
(Evaporative emission system
pressure sensor/switch range/
performance)
ECM detects a sloshing signal fro ...