Description
Light reminder warning chime does not sound even though headlamp is illuminated.
Diagnosis procedure
1.Check combination meter input signal
Select the data monitor for the meter/m&a and check the buzzer monitor value.

Is the inspection result normal? Yes >> replace combination meter. Refer to mwi-77, "removal and installation".
No >> go to 2.
2.Check front door switch lh signal circuit
Check the front door switch lh signal circuit. Refer to dlk-102, "diagnosis procedure" (with intelligent key system) or dlk-253, "diagnosis procedure" (without intelligent key system).
Is the inspection result normal? Yes >> go to 3.
No >> repair or replace harness or connector.
3.Check front door switch lh
Check front door switch lh. Refer to dlk-103, "component inspection" (with intelligent key system) or dlk- 255, "component inspection" (without intelligent key system).
Is the inspection result normal? Yes >> replace the bcm. Refer to bcs-73, "removal and installation" (with intelligent key system) or bcs-126, "removal and installation" (without intelligent key system).
No >> replace the front door switch lh. Refer to dlk-194, "removal and installation" (with intelligent key system) or dlk-341, "removal and installation" (without intelligent key system).
The seat belt reminder warning
continues sounding, or does not
sound
The key warning does not sound
(without intelligent key)ID registration cannot be completed
Diagnosis Procedure
NOTE:
The Signal Tech II Tool (J-50190) can be used to perform the following
functions. Refer to the Signal Tech II
User Guide for additional information.
Activate and display TPMS transmitter IDs
Display tire pressure reported by the TPMS transmitter
Read TPMS DTCs
...
Description
NOTE:
This vehicle is diagnosed using the CONSULT-III plus.
When CONSULT is connected with a data link connector
equipped on the vehicle side, it will communicate with the control
unit equipped in the vehicle and then enable various kinds of diagnostic
tests.
Instrument lower panel LH ...
System initialization
Description
If any of the following operations are performed, the initialization is
necessary for normal operation of power
window system.
Disconnection and connection of battery cable from negative terminal.
When power window main switch replaced.
Electric power supply to power window m ...